Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: 1353
Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0822
S49E hall sensor Features wide-range voltage comparator LM393 Signal output indicator Analog / Digital output
Reference: RBD-1202
3-axis magnetic electronic compass. Precise heading information. Operating Voltage: 3 -5 V DC. Driver Chip: HMC5883L / QMC5883L Communication: I2C protocol. Measuring range: ± 1.3-8 Gauss.Library: https://github.com/keepworking/Mecha_QMC5883Lhttps://www.arduino.cc/reference/en/libraries/qmc5883lcompass/
Reference: RBD-2073
Digital Output Hall-effect sensor. Operating voltage: typically 5V. Output Current: 25mA. It can be used to detect both the poles of a magnet.
Reference: RBD-2472
Note: Please be aware that once the connector is closed it can't be unlocked
Reference: RBD-1192
Digital Output Hall-effect sensor. Operating voltage: typically 5V. Output Current: 25mA. It can be used to detect both the poles of a magnet.
Reference: RBD-1722
Antenna Size : approx. 26 x 26 x 9 (LxWxH) mm. Module Size : approx. 26 x 36 x 4 (LxWxH) mm. Net weight : approx. 16 gm. Gross weight : approx. 17 gm. Mounting : approx. 3 mm. The default baud rate : 9600.
Reference: RBD-2120
Onboard precision microcurrent transformer. Onboard sampling resistor. The module can measure AC currents less than 5A, the corresponding analog output 5A/5mA.
Reference: RBD-2851
Shape: Circular. Sensing Area diameter (mm): 30 Min Force: 150 gm. Max Force: 20Kg. Length (mm): 42. Weight (gm): 2.
Reference: RBD-1194
Product Name : Optical Sensor Switch Model : RPR220 Color : Black Net Weigh : 3g Material : Plastic, Metal Detection Distance:1-13mm Working Voltage:DC 30V(Max) Output Type:Photo Transistor
Reference: RBD-1757
Supply Voltage: 3.3 V/ 5V. Interface Type: I²C, SPI. Sensing Range: ±2g, ±4g, ±8g, ±16g. Sensitivity: X: 28.6 LSB/g. Y: 31.2 LSB/g. Z: 34.5 LSB/g. Ultra Low Power: 40µA in measurement mode, 0.1µA in standby@ 2.5V. Free-Fall Detection. Tap/Double Tap Detection.
Reference: RBD-2224
Voltage – 250V Easy PCB mounting Good consistency Widely acclaimed
Reference: RBD-2852
Shape: Circular. Sensing Area diameter (mm): 18.3 Min Force: 20 gm. Max Force: 6Kg. Length (mm): 60. Weight (gm): 2.
Reference: RBD-1199
Low-noise output Fast power-on time Ratiometric rail-to-rail output 4.5 to 6.0 V operation Solid-state reliability Factory-programmed at end-of-line for optimumperformance Robust ESD performance
Reference: RBD-1766
Supports 5V/3.3V input Onboard RT9161 faster load the appropriate speed Ideal for noisy power environment Application: DIY project.
Reference: RBD-2342
INA3221 3 Channel Shunt Current Voltage Monitor Sensor, high-side current and bus voltage monitor with an I2C- and SMBUS-compatible interface
Reference: RBD-2853
Shape: Circular. Sensing Area diameter 5mm Min Force: 20 gm. Max Force: 1Kg. Length (mm): 65. Weight (gm): 2.
Reference: RBD-1201
Measurement range: 12 m. Operating Voltage: 5V. Power : 0.12w. Weight: 6 gm. Compatible with Pixhawk Controller. Frequency: 100Hz
Reference: RBD-1811
AS5600 Magnetic Induction Angle Measurement Sensor
Reference: RBD-2854
Measure Applied Force: Reads pressure variations for various applications. Analog and Digital Outputs: Provides flexibility for data acquisition. Adjustable Threshold: Set sensitivity based on your project requirements. Compact Design: Integrates seamlessly into various project
Reference: RBD-1203
Distance measuring range: 10 cm to 80 cm Output type: Analog voltage Output voltage differential over distance range: 2.05 V (typical) Update period: 38 ± 10 ms
Reference: RBD-1813
ICM-20948 MEMS Motion Tracking Device Sensor Board 9 Axis
Reference: RBD-2361
Working voltage: 3V-5V (MAN SV) Static output voltage: VCCi2 Working current: 135m2A (MAX) Small in size, with easy mounting capability. Monolithic Hall IC for high reliability
Reference: RBD-2860
Measure Applied Force: Reads pressure variations for various applications. Analog and Digital Outputs: Provides flexibility for data acquisition. Adjustable Threshold: Set sensitivity based on your project requirements. Compact Design: Integrates seamlessly into various project
Reference: RBD-0569
Acceleration, Gyroscope, and Magnetometer Power Supply: DC3.3V-5V Chip: MPU9250 Size: 22 mm x 17 mm. Gyro range : ± 250 500 1000 2000 ° / s Acceleration range: ± 2 ± 4 ± 8 ± 16g Magnetic field range: ± 4800uT 9 DOF modules
Reference: RBD-1204
Distance measuring range: 100 cm to 550 cm Output type: Analog voltage Output voltage differential over distance range: 2.05 V (typical) Update period: 38 ± 10 ms
Reference: RBD-2653
2.8V-5.5V to ±12V DC Conversion Step Up Power Supply Module is straightforward. There is a 2.8 to 5.5 V DC input and the module outputs +12 V and -12 V DC dual power supply voltage with a current rating of a maximum 30 mA. Off course the current output is low but sometimes it suits in many situations where one is looking forward for a small boost...
Reference: RBD-2918
EMG muscle sensor V3.0 with cable and electrodes Measures the electrical activity of muscles High signal quality for accurate and reliable measurement Adjustable gain and filtering for signal conditioning Compatible with various types of microcontrollers and data acquisition systems Comes with reusable electrodes and a 3.5mm jack cable for easy connection
Reference: RBD-1205
Distance Range (Radius): 0.15m to 6m, white objects (Diameter Range – 12m) Angular Range: 0 ~ 360º Distance Resolution: < 0.5mm Angular Resolution: <= 1 º Sample Duration: 0.5 ms Sample Frequency: >=8000 Hz Scan Rate: 1 ~ 10Hz, Typical 5.5Hz
Reference: RBD-2675
You can also use the IICLCD1602 LCD to display voltage. By 3P connector, connect this module with the expansion of board Arduino Voltage input range: DC 0-25 V Voltage detection range: DC 0.02445 V to 25 V Voltage analog resolution : 0.00489 V
Reference: RBD-1206
Scanning Range: 18M Radius Detection Range: 12M Radius 4cm Ultra-thin Ideal for all kinds of service robot. 8000 times sample rate, the highest in the current economical LIDAR industry 360-degree laser range scanning Low Noise, Brushless Motor New Non-contact Drive OPTMAG Original Design, prolong the life-span Class 1 Laser Safety Standard High-speed...
Reference: RBD-1919
Acceleration, Gyroscope, and Magnetometer Power Supply: DC3.3V-5V Chip: MPU9250 Gyro range : ± 250 500 1000 2000 ° / s Acceleration range: ± 2 ± 4 ± 8 ± 16g Magnetic field range: ± 4800uT 9 DOF modules
Reference: RBD-2677
Operating on a 5V DC power supply with a current consumption of less than 60mA, this 0.28-inch Digital Voltmeter Ammeter is a versatile tool for measuring voltage and current. With a testing range of 0-100V for voltage and 1-100A for current, this meter offers precise measurements with easy readability, even in dim light conditions.