Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: RBD-1360
PN junction rectifier diode. One direction flow of Current. Used for conversion of AC power to DC. 1N 4007 is electrically compatible with other rectifier diodes Used instead of any of the diode belonging to 1N400X series
Dust sensor used in detecting very fine particles like smoke,cigarette smoke and more. Optical air quality sensor designed to sense dust particles. Get the variations of Dust sensors at Robotics Bangladesh.
Reference: RBD-0338
Brand: Waveshare
Sharp GP2Y1010AU0F onboard, Detecting fine particle larger than 0.8μm Low power consumption Analog voltage output The output level is linear with dust density Check out New Product Optical Dust Sensor- GP2Y1010AU0F
Reference: RBD-0419
Features: Built-in Red, IR, and Green LEDs 5V operation (3.3V is allowed, but green LED is not guaranteed to operate) Applications include presence detection, distance sensing (18" max), pulse oximetry, blood oxygen saturation level (SpO2), smoke and particle detection Documents: Schematic Eagle Files Hookup Guide Datasheet (MAX30105) MAX3010x Sensor...
Reference: RBD-0441
Power supply voltage: DC5 ± 2V Sensitivity: 0.5V / (0.1mg / m3) The minimum detection level of particles: 0.8 m Clean air voltage: 0.9V typ. Low consumption current (Icc: MAX. 20 mA) The presence of dust can be detected by the photometry of only one pulse Enable to distinguish smoke from house dust RoboticsBD
Reference: RBD-0812
Based on MAX30105 – heart rate, oximeter, smoke sensor Green, red, and infra-red LEDs Interface: I2C (address 0x57) Compatible with 3.3V and 5V logic levels.
Reference: RBD-0813
Operating Voltage: 5VDC. Current: 30mA (MAX). Operating temperature: -30 ° C to 80 ° C. Compatible with Arduino, Raspberry Pi, AVR, PIC, etc. Measuring Range: 0 ~ 1000 NTU.
Reference: RBD-0958
Five Operating Modes Integrated MCU Onboard Processing Standard I2C Digital Interface Optimized Low-Power Modes Optional NTC Thermistor Pins
Reference: RBD-1042
Operating Voltage: 3.3 ~ 5.5 VDC. Operating Current: 5mA. Interface: PH2.54-3P. Dimensions mm(LxWxH): 98 x 23 x 4. Supports 3-Pin Gravity Sensor interface Analog output. Weight (gm): 15.
Reference: RBD-1716
Working Voltage: 5.0V Maximum Working Current: 100mA Data Interface Level: L<0.8V, H>2.7V, maximum voltage level 3.3V Particle Measurement Range: 0.3 ~ 1.0μm; 1.0 ~ 2.5μm; 2.5 ~ 10μm Note: Please purchase this adapter board to use it with Arduino and Raspberry Pi.
Reference: RBD-1719
Envitec Honeywell OOM202 Medical Ventilator Oxygen Sensor Made in GermanyManufacture Date: 2023 December
Reference: RBD-2289
Low cost, compact size dust sensor module Used to quantitative particle (> 1 micron) measurement Principle of particle counter Can sense the tobacco smoke and pollen, house dust Consist of light emitting diode lamp, detector, signal amplifier circuit and heater Used in applications such as the air cleaner or air purifier Users can use this sensor...
Reference: RBD-1751
Detection Gas: H2, Alcohol, CO, VOC Detection Range: 10~500ppmH2 5~500ppm Alcohol 10~500ppm CO Air Quality Sensor Module
Reference: RBD-1654
5 In 1 Portable CO2 Detector Air Quality Detector Intelligent Air Detector Temperature and Humidity Sensor Carbon Dioxide Monitor TVOC Formaldehyde Detection HCHO Detector Color Black
Reference: RBD-2330
AS7343 14-channel spectral sensor covering 380nm to 1000nm (VIS to NIR range) Features 12 visible spectrum channels, 1 near-infrared channel, and clear/flicker detection channels Optimized for reflective, transmissive, and emissive measurements in consumer and industrial applications Compact design with I²C interface for easy integration Ideal for color...
Reference: RBD-2508
The ENS160 is a digital multi-gas sensor specifically designed for indoor air quality testing that optimizes the detection of a wide variety of gases and volatile organic compounds (VOCS), including toluene, hydrogen, ethanol, N02 and ozone. The air quality sensor is used in home and building automation, consumer products, electrical and air purification
Reference: RBD-2560
Introducing the Dust Sensor - an optical sensing system designed for detecting airborne dust particles using an infrared emitting diode (IRED) and a phototransistor. The diode and phototransistor are diagonally arranged to effectively capture reflected light from dust in the air. Notably, this sensor is highly efficient in detecting very fine particles,...
Reference: RBD-2729
The SGP41 from Sensirion is an innovative VOC and NOx sensor engineered to serve as a digital smart switch and regulation unit in air treatment systems like air purifiers. Utilizing Sensirion's advanced Gas Index Algorithm, the sensor accurately processes two distinct signals, enabling automatic triggering of air treatment devices for the removal of...
Reference: RBD-2730
The SGP40 is a digital gas sensor designed for easy integration into air purifiers or demand-controlled ventilation systems. Sensirion’s CMOSens® technology offers a complete, easy-to-use sensor system on a single chip featuring a digital I2C interface and a temperature-controlled micro hotplate, providing a humiditycompensated VOC based indoor air...
Reference: RBD-3001
Brand: DFRobot
As the most basic part of life, air is attracting more and more attention, for example, the most common PM2.5, PM1.0, PM10, etc. Keeping an eye on the quality of the air we breath is becoming quite important. DFRobot brings you this Air Quality Sensor that can measure particulate matter like PM2.5, PM1.0, PM10. With easy-to-use Gravity interface, the air...
Reference: RBD-3171
Sensirion SPS30 Particulate Matter Sensor - PM2.5 Air Quality Monitoring and Control The Sensirion SPS30 is a state-of-the-art optical particulate matter (PM) sensor designed for accurate air quality monitoring. Utilizing advanced laser scattering technology and Sensirion’s innovative contamination-resistance technology, this sensor provides superior...
Reference: RBD-3176
The Sensirion SCD30 is a high-quality Nondispersive Infrared (NDIR) CO₂ sensor that integrates temperature and humidity sensing, making it an all-in-one solution for air quality monitoring. With a measurement range of 400 ppm to 10,000 ppm and an accuracy of ±(30 ppm + 3%), the SCD30 delivers reliable and precise readings for environmental and industrial...
Reference: RBD-3182
The PlanTower PMSA003-C is a high-precision laser dust sensor designed for determining air purity by measuring PM1.0, PM2.5, and PM10 particle concentrations. This sensor detects particulate matter ranging from 0.3 µm to 10 µm in size, including pollutants like cigarette smoke and vehicle emissions. With a built-in low-noise fan and advanced laser light...
Reference: RBD-3183
The PlanTower PMSA003-A is a high-precision laser dust sensor designed to measure air purity by detecting PM1.0, PM2.5, and PM10 particle concentrations. This sensor effectively identifies particles as small as 0.3 μm in diameter, including pollutants such as cigarette smoke and car exhaust fumes. With its UART communication interface and a wide operating...
Reference: RBD-3185
The PMS7003 Dust Sensor is a highly precise module designed to monitor air quality by measuring particulate matter (PM) concentrations, including PM1.0, PM2.5, and PM10. This sensor detects particles as small as 0.3 µm, making it ideal for monitoring pollutants such as cigarette smoke and vehicle exhaust. Its compact design and advanced laser-based...
Reference: RBD-3190
The IDC 10-pin to MicroUSB Adapter is specifically designed for the PMS7003 air purity sensor, allowing seamless signal transmission from a 10-pin IDC connector to a microUSB interface. This adapter enables direct connection of the PMS7003 sensor to a computer, simplifying data analysis and integration into various projects.