• How to Place an Order

  • Store Pick Up

  • Request for Quotation/ International Sourcing

  • Order Status

Jumper Wire Single 20cm Robotics Bangladesh Quick view

Reference: RBD-1354

Jumper Wire Single 20cm

Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.

Price BDT 3
More
Out of Stock
Choose Your Size Quick view

Reference: 0984

Heat Shrink Tube

Choose your desire Heat Sink Size from below: 

Price BDT 2
More
In-Stock
MIFARE Classic 1K RFID NFC Smart Card 13. Quick view

Reference: RBD-0351

MIFARE Classic 1K RFID NFC Smart Card 13.56MHz Printable

Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...

Price BDT 33
More
Out of Stock
470 Ohm 1/4w - Pack of 5 Quick view

Reference: 0245

Kiloohm (KΩ) 1/4w Resistors - Pack of 5

Choose your desire Resistor value from below: 

Price BDT 5
More
In-Stock
Jumper Wire 40 Pcs Set 20cm Robotics Bangladesh Quick view

Reference: 0031

Jumper Wire 40 Pcs Set 20cm

3 Types Available (Please select from option) 1. Male to Male  2. Male to Female 3. Female-Female

Price BDT 100
More
Product available with different options
Buzzer Quick view

Reference: 0766

Ohm (Ω) 1/4w Resistors - Pack of 5

Choose your desire Resistor value from below: 

Price BDT 5
More
In-Stock
5 mm Green LED (Pack of 5) Quick view

Reference: RBD-0768

5 mm Red LED (Pack of 5)

Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent

Price BDT 5
More
In-Stock
Push Button Switch (2PIN) Robotics Bangladesh Quick view

Reference: RBD-0761

Push Button Switch (2PIN)

Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical

Price BDT 5
More
In-Stock
Buzzer Quick view

Reference: RBD-0758

BC547 NPN Transistor

BC547 NPN DIP Transistor

Price BDT 4
More
In-Stock
Jumper Wire Single 30cm Robotics Bangladesh Quick view

Reference: 1353

Jumper Wire Single 30cm

Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.

Price BDT 5
More
In-Stock
All best sellers
Omron
  • Omron

Omron CJ1G CPU45H

RBD-0845
Call For Price
01783 007 004
Quantity

Only 4 items left in stock
  • Store Pickup Available! Store Pickup Available!
  • Free Ship Over 5000 BDT Free Ship Over 5000 BDT
  • Quality Product Quality Product
  • No Warranty No Warranty
  • No Replacement No Replacement
Omron CJ1G CPU45H PLC 

Specifications

 

Item Specification
Product name Loop-control CPU Unit
Model numbers CJ1G-CPU[][]P
Data
exchange
method
with
CPU Unit
Words in Auxiliary
Area in CPU Unit
Loop Controller → CPU Unit:
Operation status, PV error input ON, MV error input ON, occurrence of execution error, function block database error, cold start ready for hot start command, flash memory backup in progress, function blocks changed, etc.
CPU Unit → Loop Controller:
Hot/cold start command at power ON
User allocations
in I/O memory
User memory tables used to allocate function block ITEM data for user-specified memory in the CPU Unit (CIO, Work, HR, DM, or EM Area (bank 0, but also banks 1 to 12 for Ver. 3.0 or later)).
EM Area (bank
number)
allocations (for
SCADA software)
HMI function used allocate function block ITEM data for Control, Operation, External Controller, and System Common blocks in the specified bank of the EM Area in the CPU Unit.
The real PV in calibration mode can be allocated (Ver. 3.0 or later).
Setting None
Indicators Loop-control CPU Units: 2 LEDs (RUN and ready)
Super capacitor backup data All function block data (including Step Ladder Program commands), stored error log data
Super capacitor backup time CJ Series (CJ1G-CPU[][]P): 5 min at 25 ° C (Backed up by the Battery in the CPU Unit.)
Data stored in flash memory Function block data
Backup from RAM to flash memory Executed from CX-Process Tool (as required).
Recovery from flash memory to RAM Automatic at power ON if startup mode is set for a cold start, or executed from CX-Process Tool (as required).
Influence on CPU Unit cycle time Loop-control CPU Unit (CJ1G-CPU[][]P): 0.8 ms max. (Depends on function block contents.)
Current consumption
(supplied from Power Supply Unit)
Loop-control CPU Unit: 1.06 A at 5 VDC
Note: Increased by 150 mA when NT-AL001 Link Adapter is used.
Standard accessories None

 

Function Specifications

 

Item Description
Operation method Function block method
Number of
function
blocks
  Total
CJ1G-CPU42P: 71 blocks max., CJ1G-CPU43/44/45P: 501 blocks max.
Analog
operation
Control
Blocks
PID and other control functions LCB01: 50 blocks max.,
LCB03: 300 blocks max.
Control
Blocks
Blocks
Alarm, square root operation, time operations, pulse train operation, and other operation functions for various processes
Sequential
Control
Step
Ladder
Program
block
Logic sequence and step sequence functions 4,000 commands max.
100 commands/1 block max.
Can be divided into 100 steps max.
100 commands/1 step max.
I/O block Field
Terminal
block
Analog I/O function with Analog I/O Unit, contact I/O function with Basic I/O Unit 80 blocks max.
User
link
tables
Analog data I/O and contact data I/O function for CPU Unit
Can be added to CSV tags.
2,400 data max.
HMI
function
I/O function for function block ITEM data for Control, Operation, External Controller, and System Common blocks for CPU Unit Control/Operation Blocks
LCB01: 50 blocks max. + 20
send/receive words
LCB03: 300 blocks max. + 20
send/receive words
System Common Block
20 send/receive words
Real PV Input Monitor Area
LCB01: 50 words max.
LCB03: 300 words max.
System Common block System common operation cycle setting, run/stop command, load rate monitor, etc. Single block
Function block data preparation/
download
Function block data prepared by CX-Process Tool (sold separately) and downloaded to Loop Controller
Execution
of
function
blocks
Function
block
execution
conditions
Common
to all
function
blocks
Operation of all function blocks by turning power ON to the PLC (Hot or cold start can be specified.) For cold starts, function block data is transferred from flash memory to RAM.
Function block operation can be stopped by CX-Process Tool or FINS command.
Hot start (state active before Board was stopped is continued before operation is started) or cold start (all state signals and function block internally held values are cleared before operation is started) is possible by CX-Process Tool or FINS command.
For
individual
function
block
Function block operation can be stopped and hot start (state active before Unit was stopped is continued before operation is started) is possible by CX-Process Tool or FINS command.
Function block
operation cycle
Standard: 
Operation of all function blocks is executed at the same operation cycle preset to ITEM 004 in the System Common block.
Settable operation cycles: 0.1 s, 0.2 s, 0.5 s, 1 s, 2 s (default: 1 s)
Note: Cannot be set to the same operation cycle for some function blocks.
Option: 
Operation of individual function blocks is executed at the same operation cycle preset to ITEM 004 in the System Common block.
Settable operation cycles: 0.01 seconds, 0.02 seconds, 0.05 seconds, 0.1 seconds, 0.2 seconds, 0.5 seconds, 1 second, and 2 seconds (default: 1 second)
Note:
The external I/O response cycle on a single control loop does not necessarily match the operation cycle. The response cycle is heavily dependent on the CPU Unit's cycle time. (See the external I/O response cycle item below.)
Function blocks
supporting
high-speed operation
The following operation cycles can be set for the blocks listed below: 0.01, 0.02, and 0.05 s.
Control/Operation blocks: Block Models 016, 150, 151, 155 to 157, 167, 182 to 184, 186, and 221 to 224
Sequence control and Field Terminal blocks
Execution
of
function
blocks
LCB load rate The "LCB load rate" refers to the ratio between the actually applied execution time and preset operation cycle.
The maximum value and current value are displayed for each operation cycle group on the CX-Process Tool.
A LCB load rate of 80% or less is required in all operation cycle groups.
When the load rate exceeds 80% for 6 seconds, the LCB load rate automatically changes to the next longer operation cycle. (This is called the "automatic operation cycle switching function.")
Note:
The High Load Alarm Flag (A42408) turns ON if the load rate exceeds 80% for 6 seconds consecutively (non-fatal Inner Board error). (If execution is not possible within the operation cycle, the operation cycle will be extended.) If this happens, select the function blocks that can have longer operation cycles and increase their operation cycles. If the load rate is still too high, processing of the function blocks must be separated for processing by additional Loop Control Units.
External I/O response cycle The time from external input of analog signals up to external output of analog signals on a single control loop depends on the function block's operation cycle and the CPU Unit's cycle time.
Internal
Operation
Number of control
loops
The maximum number of loops that can be used if the LCB load rate is 80% for a standard applications (e.g., with each loop consisting of one Ai4 Terminal, Segment Linearizer, Basic PID, and A04 terminal) is shown in the following table.
CJ1G-CPU43P/44P/45P (LCB03)
Operation cycle: Maximum number of loops
0.01 s: 20 loops 0.02 s: 35 loops 0.05 s: 70 loops
0.1 s: 100 loops 0.2 s: 150 loops 0.5 s: 150 loops
1 s: 150 loops 2 s: 150 loops  
CJ1G-CPU42P (LCB01)
Operation cycle: Maximum number of loops
0.01 s: 20 loops 0.02 s: 25 loops 0.05 s: 25 loops
0.1 s: 25 loops 0.2 s: 25 loops 0.5 s: 25 loops
1 s: 25 loops 2 s: 25 loops  
Number of operations
for process
(excluding control)
LCB01: Max. 50 blocks
LCB03: Max. 30 blocks
Sequential
control
(Use only
one or the
other)
Step
ladders
LCB01: Max. 20 blocks per Board and total max. 2,000 commands per Board
LCB03: Max. 200 blocks per Board and total max. 4,000 commands per Board
Loop Controllers common: Divisible to 100 commands max. per block and 100 steps max. per block (100 commands max. per step)
Control
method
PID control PID with 2 degrees of freedom
Possible control type
combinations
Basic PID control, cascade control, feedforward control, sample PI control, dead time compensation, PID control with differential gap, override control, program control, time-proportional control and other control types can be achieved by combining function blocks.
Alarm Integrated into PID
block
4 PV alarms (high/high limit, high limit, low limit, low/low limit) per PID block, 1 deviation alarm
Alarm block High/Low Alarm block, Deviation Alarm block
Internal analog signal Min. - 320.00% to max. +320.00%
Scaling of the engineering units depends on the CX-Process Tool (sold separately).
Operating status monitor method Executed by commercially available SCADA software. In the SCADA software, CSV tags set on the
CX-Process Tool are specified.
External
I/O
External I/O signals By data exchange with Analog I/O Unit via the Field Terminal block Total number of I/O points:
(max. 8 points on Analog Input Unit or Analog Output Unit, or max. 96 points on Basic I/O Unit) × 80 blocks
External contact I/O
signals
By data exchange with Basic I/O Unit via the Field Terminal block
CPU Unit analog data
I/O
By data exchange with CPU Unit I/O memory via user link tables Total number of I/O points: 2400
CPU Unit contact data
I/O
By data exchange with CPU Unit I/O memory via user link tables
Analog/contact I/O
with SCADA software
Data transfer between Loop Controller and I/O memory in CPU Unit for Control, Operation, and External Controller blocks using HMI function CJ1G-CPU42P: 2,040
CJ1G-CPU43/44/45P: 12,040
FINS command to
Loop Controller
Read/write of ITEMs in Loop Controller function blocks and execution of run/stop commands are possible from the CPU Unit (including other networked nodes) or host computer by issuing the following FINS commands to the Loop Controller.
READ MULTIPLE ITEMS IN FUNCTION BLOCK (0240 HEX)
WRITE MULTIPLE ITEMS IN FUNCTION BLOCK (0241 HEX)
READ ITEM IN MULTIPLE FUNCTION BLOCKS (0242 HEX)
WRITE ITEM IN MULTIPLE FUNCTION BLOCKS (0243 HEX)
READ UNIT INFORMATION (0501 HEX)
ECHOBACK TEST (0801 HEX)
READ ERROR LOG (2102 HEX)
CLEAR ERROR LOG (2103 HEX)
System
common
status
signals
Status output signal
for sequence control
Constantly ON flags, constantly OFF flags, clock pulse (ON/OFF every 0.5 and 1 seconds)
Clock timing output
signal
Differential output at 00:00 every day, noon every day, every 10 minutes, every minute and every 10 seconds
Note: The CPU Unit's clock data are read as these clock data.
Calendar/clock output
signal
Year, year/month, month/hour, day/time, hour/minute and minute/second
Noye: The CPU Unit's clock data is read as these clock data.
Error display By front panel indicators: hardware test error, function block database error, battery error
Storage of function block execution-related error codes to ITEM 003 of each function block: source/destination designation error, illegal function block combination, illegal parameter, etc.

 

Software Specifications

The following software (sold separately) is required to use the Loop Controller: 
• CX-Process Tool (included in CX-One): Tool for preparing function block data (essential)

CX-Process Tool Specifications

 

Item Specification
Product name CX-Process Tool (Included in CX-One Package)
Applicable PLCs CS/CJ-series
Applicable
computer
Computer IBM PC/AT or compatible
Operating system
(OS) *1 *2
Japanese or
English System
Microsoft Windows XP (Service Pack 3 or higher), Vista or 7
CPU Proceccor recommended by Microsoft.
Memory Memory recommended by Microsoft.
Hard disk Approx. 2.8 GB or more of available memory is required to install all of the CX-One.
Display XGA (1,024 × 768). High Color (16-bit) or higher.
Disk Drive CD-ROM or DVD-ROM drive
Software that must be installed
with the CX-Process Tool
CX-Server or FinsGateway
Connecting
method
Connection
with CPU Unit
(or Serial
Communications
Board/Unit)
Using FinsGateway
Serial Unit Driver
Communications protocol with PLC: Host Link or Peripheral Bus *2
Connect the computer to the peripheral port or built-in RS-232C port of the
CPU Unit, or the RS-232C port of a Serial Communications Unit/Board.
Connecting cable:
When connecting to the CPU Unit peripheral port: CS1W-CN[][][] (2 m, 6 m)
When connecting to the CPU Unit's RS-232C port: XW2Z-[][][]-[] (2 m, 5 m)
Using CX-Server Communications protocol with PLC: Host Link or Peripheral Bus
(The compatible connecting cables are the same as the ones shown above
for the FinsGateway connection.)
Connection
via Controller
Link
Using FinsGateway
CLK (PCI) Driver
Install the driver in a computer equipped with a Controller Link Support
Board (PCI slot) to support communications between the computer and
PLCs equipped with a Controller Link Unit.
Using FinsGateway
Controller Link
Driver or CX-Server
Install the driver in a computer equipped with a Controller Link Support
Board (ISA slot) to support communications between the computer and
PLCs equipped with a Controller Link Unit.
Connection
via Ethernet
Using FinsGateway
ETN_UNIT Driver
or CX-Server
Install the driver in a computer equipped with an Ethernet to support
communications between the computer and PLCs equipped with an
Ethernet Unit.
Offline operation functions Setting of function block ITEM data (including System Common block settings)
Software wiring of analog signals
Inserting, and printing text-string comments (memos) in block or ladder diagrams.
Describing Step Ladder Program block commands
Creating sequence tables
Online operation functions Downloading of function block data (download/upload to and from Loop Controller)
Run/stop command for Loop Controller (all function blocks)
System monitor run status: Monitoring/manipulation of System Common block (Block Model 000)
(including monitoring of LCB load rate)
Loop Controller monitor run status: Confirmation of function block wiring operation (including
operation stop/stop cancel on each function block), confirmation of Step Ladder Program operation,
and validation of sequence tables
Initializing Loop Controller memory (RAM)
Autotuning PID constants and other parameters.

What is the price of Omron CJ1G CPU45H in Bangladesh?

The latest price of Omron CJ1G CPU45H in Bangladesh is BDT 0 You can buy the Omron CJ1G CPU45H at best price from our RoboticsBD or visit RoboticsBD Office.

Please note that the product information provided on our website may not be entirely accurate as it is collected from various sources on the web. While we strive to provide the most up-to-date information possible, we cannot guarantee its accuracy. We recommend that you always read the product labels, warnings, and directions before using any product.

Product Images are shown for illustrative purposes only and may differ from the actual product.

Product Details
RBD-0845
24 other products in the same category:
Omron Quick view

Reference: RBD-0868

Omron CPM1A-20EDR1

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0865

Omron CQM1-0D212

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0855

Omron CJ1W-OD212

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0852

Omron CJ1W-MD233

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0869

Omron CPM1A-20CDR-A

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0846

Omron CJ1M-CPU11

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0861

Omron CQM1-ID212

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0866

Omron CPM2A-60CDR-A

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0854

Omron CJ1W-OD202

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0850

Omron CJ1W-ID231

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0848

Omron CJ1W-IC101

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0851

Omron CJ1W-ID232

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0849

Omron CJ1W-ID211

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0860

Omron CQM1-PA203

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0858

Omron CJ1W-SCU41-V1

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0864

Omron CQM1-CPU11

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0867

Omron CPM1A-40CDR-D-V1

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0853

Omron CJ1W-OC211

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0856

Omron CJ1W-OD233

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0857

Omron CJ1W-OD262

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0862

Omron CQM1-IA121

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0847

Omron CJ1W-AD041-V1

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0859

Omron Cj1w-ii101

Call For Price 01783 007 004

More
In stock
Omron Quick view

Reference: RBD-0863

Omron CQM1H-CPU51

Call For Price 01783 007 004

More
In stock