Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: 1353
Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0674
Model: MQ-5 Operating Voltage: 5V DC Operating Temparature:-20~40 degree celcius
Reference: RBD-0675
Model: MQ-6 Operating Voltage: 5V DC Detecting Range:200-10000 ppm Relative Humidity:<95% RH
Reference: RBD-0676
Operating voltage: DC 5 V. The analog output voltage, the higher the concentration the higher the voltage. The carbon monoxide detection with better sensitivity. With a long service life and reliable stability. Rapid response and recovery characteristics. Range: 10 to 1000 ppm. RoboticsBD
Reference: RBD-0677
Using high-quality dual-panel design, with power indicator and TTL signal output instructions. The switching signal having a DO (TTL) output and analog output AO. TTL output valid signal is low. The higher the voltage, the concentration of the analog output voltage is higher. A hydrogen gas detection with good sensitivity. Has a long life and reliable...
Reference: RBD-0678
Good sensitivity to CO/Combustible Gas High sensitivity to Methane, Propane, and CO Long life and low cost Simple drive circuit Input voltage: DC 5±0.2V Current Consumption: 150mA
Reference: RBD-0679
Sensitivity to Ammonia, Sulfide and Benzene steam Sensitive for benzene, alcohol, smoke Fast response and recovery Adjustable sensitivity. RoboticsBD Signal output indicator Output voltage boosts along with the concentration of the measured gases increases.
Reference: RBD-0680
Acceleration, Gyroscope, and Magnetometer Power Supply: DC3.3V-5V Chip: MPU9250 Size: 22 mm x 17 mm. Gyro range : ± 250 500 1000 2000 ° / s Acceleration range: ± 2 ± 4 ± 8 ± 16g Magnetic field range: ± 4800uT 9 DOF modules. RoboticsBD
Reference: RBD-0685
Detection distance: 2 ~ 30cm Detection angle: 35 ° Comparator chip: LM393 3mm screw holes for easy mounting
Reference: RBD-0812
Based on MAX30105 – heart rate, oximeter, smoke sensor Green, red, and infra-red LEDs Interface: I2C (address 0x57) Compatible with 3.3V and 5V logic levels.
Reference: RBD-0923
Measuring range: temperature -40-80 ℃; humidity 0; 99.9%RH Measurement accuracy (25℃): temperature: + 0.5; humidity: + 2%RH (10; 90%RH) Resolution: temperature: 0.1 ℃, humidity: 0.1%RH Attenuation value: temperature: <1℃ / year; humidity: < 1%RH/ years High precision Capacitive type Full range temperature compensated Relative humidity and...
Reference: RBD-0948
Built-in Flash: 32Mbit Power supply: 5V WiFi protocol: IEEE 802.11 b/g/n Peripheral interface: UART/GPIO/ADC/DAC/SDIO/PWM/I2C/I2S Logic level: 3.3V
Reference: RBD-1175
Low-noise analog signal path Device bandwidth is set via the new FILTER pin 5 µs output rise time in response to step input current Small footprint, low-profile SOIC8 package 2.1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8 Supply Voltage: 4.5V~5.5V DC Measure Current Range: 20A Sensitivity: 100mV/A
Reference: RBD-1174
Low-noise analog signal path. Device bandwidth is set via the new FILTER pin. 5 µs output rise time in response to step input current. Small footprint, low-profile SOIC8 package. 2.1 kV RMS minimum isolation voltage from pins 1-4 to pins 5-8.
Reference: RBD-1201
Measurement range: 12 m. Operating Voltage: 5V. Power : 0.12w. Weight: 6 gm. Compatible with Pixhawk Controller. Frequency: 100Hz
Reference: RBD-1377
Module Name:CJMCU-4541 Sensor: MICS-4514 Type: Carbon Monoxide Nitrogen Oxygen Sensor
Reference: RBD-1380
Sharp GP2Y0A02YK0F IR Range Sensor - 20 cm to 150 cm Infrared range finder 20cm (~8") to 150cm (~60") Distance measuring range: 20 cm to 150 cm (8″ to 60″) Output type: Analog voltage Output voltage differential over distance range: 2.05 V (typical) Update period: 38 ± 10 ms
Reference: RBD-1424
Onboard precision microcurrent transformer. Onboard sampling resistor. The module can measure AC currents less than 5A, the corresponding analog output 5A/5mA. Rated input current: 5A Rated output current: 5mA Change: 1000: 1 The linear range: 0 ~ 10A (100 ohms) Linearity: 0.2%
Reference: RBD-1644
940nm laser classified as class 1 under operation condition by IEC 60825-1:2014-3rd edition Small ceramic package(20×13.2×2.0mm) Long range absolute range measurement up to 1.8m within 5% accuracy at indoor
Reference: RBD-1645
Voltage operation: 2.7V-5V Measuring distance: 4 to 50 cm Output: Digital (I/C) / Analog Output Sensor: Infrared LED and CMOS image sensor
Reference: RBD-1648
FPC1020A is a secondary development module for fingerprint recognition designed for SCM. Fingerprint identification capacity: 150 fingerprints, identification time is less than 1 second, can be customized large capacity Capacitive surface array semiconductor fingerprint sensor Support finger 360 rotation recognition Supported Operating Systems: Windows
Reference: RBD-1677
Contact Rating: 10 W. Switching Voltage: 220 V. Switching Current: 0.5 A. Breakdown Voltage: 220 VDC. Carry Current: 1 A. Contact Resistance: 100 mΩ.
Reference: RBD-0569
Acceleration, Gyroscope, and Magnetometer Power Supply: DC3.3V-5V Chip: MPU9250 Size: 22 mm x 17 mm. Gyro range : ± 250 500 1000 2000 ° / s Acceleration range: ± 2 ± 4 ± 8 ± 16g Magnetic field range: ± 4800uT 9 DOF modules
Reference: RBD-1856
Dual channel stereo, high output power (3 w + 3 w power @ 5V and 4 ohms load).. Double panel wiring solves crosstalk. Super mini design allows it to be easily placed in a variety of digital products. 3W Output at 10% THD with a 4ΩLoad and 5V Power Supply. Filterless, Low Quiescent Current and Low EMI and Low Noise. Short Circuit Protection and Thermal...
Reference: RBD-1919
Acceleration, Gyroscope, and Magnetometer Power Supply: DC3.3V-5V Chip: MPU9250 Gyro range : ± 250 500 1000 2000 ° / s Acceleration range: ± 2 ± 4 ± 8 ± 16g Magnetic field range: ± 4800uT 9 DOF modules
Reference: RBD-1934
Dual signal output (analog output and TTL level output) The TTL output effective signal is low. Analog output 0 ~ 5V voltage, the higher the concentration the higher the voltage. Good sensitivity to hydrogen sulfide, liquefied gas, natural gas, city gas, and smoke. with long service life and reliable stability fast response recovery characteristics
Reference: RBD-1942
Actuation Distance : 15 – 25 mm; Connecting cable length: 30 cm. Magnetic sensor alarm, control the switch of the circuit via the built-in magnet Alarm when someone intrudes into your places Can be used in places like apartment, hotel, office, etc.
Reference: RBD-1946
Comes with the BME280 sensor. Pressure accuracy of ±1 hPa. Temperature accuracy ±1.0°C. Altimeter accuracy ±1 meter. Humidity: +-3%
Reference: RBD-2056
Mounting form Polish rod probe The Probe material: Stainless steel Probe diameter: 4mm Length of the probe: 30mm Cabel material Silver plated copper (not insulated), PTFE Silver plated copper (Waterproof, insulated) Accuracy ±(0.3°C+0.5%|t|) Thermal response time: <0.5s
Reference: RBD-2132
GSR Galvanic Skin Response Module for measuring skin resistance and conductivity Size: 34mm x 25mm Power interface pin for easy connectivity Working current: 1mA Power voltage: 3.3-5V
Reference: RBD-2144
Automatic induction: to enter the sensing range Ultra-small size. Repeatable trigger Wide operating voltage range Micropower: quiescent current <50 Output high signal: easy docking and all kinds of circuits.
Reference: RBD-2147
The built-in 24bit AD converter. Immersion gold PCB, high quality, machine welding process to ensure quality. Power supply: 3 – 5V ( internal low dropout regulator ). Communication modes: Standard the IIC / SPI communication protocol.
Reference: RBD-0564
Onboard precision microcurrent transformer. Onboard sampling resistor. The module can measure AC currents less than 5A, the corresponding analog output 5A/5mA. Rated input current: 5A Rated output current: 5mA Change: 1000: 1 The linear range: 0 ~ 10A (100 ohms) Linearity: 0.2%