Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: 1353
Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Selecting the most reliable sensor for any Application is quite tricky as you need to think over various specs like its size, accuracy, operating specifications, and most importantly, its price. Here, we carry around 150+ differential sensors with all technical specifications and its application guidelines to narrow down your search filters which gives the highest level of satisfaction to you. Explore a wide range of best-picked sensors by Robotics Bangladesh from top brands at sensible prices in Bangladesh.
Subcategories
Reference: RBD-0041
Bases at CSR BC04 Bluetooth technology. with build-in 2.4GHz PCB antenna It’s at the Bluetooth class 2 power level. Range test: 10 meters Operating voltage: 3.3V to 6V DC Operating current in pairing is in the range of 30~40mA.
Reference: RBD-0431
Working temperature : -10℃ ~ 50℃ Working humidity : below saturation point Storage temperature : -20℃ ~ 80℃ RoboticsBD
Reference: RBD-0311
Working Voltage: 5 to 18V DC (min tested working voltage 4.5V). RoboticsBD Max current draw: 15mA @ 5V. Working Flow Rate: 1 to 30 Liters/Minute. Maximum water pressure: 2.0 MPa. Flow rate pulse characteristics: Frequency (Hz) = 7.5 * Flow rate (L/min). RoboticsBD
Reference: RBD-0671
Operating Voltage:+5V Preheat Duration:20 s Analog Output Voltage:0 to 5 V Dimension:36x20x21 mm. RoboticsBD
Reference: RBD-1111
This is one open-source Geiger Counter project which could be used to detect nuclear radiation. The schematic and code and other helpful files are listed in this package. All the codes are designed and tested on this kit, these materials are useful for DIY Geiger Counter Kit Nuclear Radiation Detectors or Radiation Monitoring Stations. Note: The kit comes...
Reference: RBD-2352
LD2410B is a high-sensitivity 24GHz human presence status sensing module developed by Hilink Electronics. Its working principle is to use FMCW frequency-modulated continuous wave to detect human targets in the set space. Combined with radar signal processing and accurate human body sensing algorithms, it realizes high-sensitivity human presence status...
Reference: RBD-0355
Description:Working voltage: 4.5V to 5.5 V.Transmit tube pressure drop: Vf = 1.6 VTransmit tube current: 20 mASignal output: A, B two way; The TTL levelDistinguish precision: 0.01 mmMeasurement frequency, 100 KHZEncoder diameter: 24 mmEncoder type D hole diameter: 4 mmThe encoder resolution: 20 line
Reference: RBD-0672
Power requirements: 5 VDC @ ~165 mA (heater on) / ~60 mA (heater off). Current Consumption: 150mA. RoboticsBD DO output: 0.1 and 5V. AO output: 0.1- 0.3 V (relative to pollution), the maximum concentration of a voltage of about 4V Detecting Concentration: 0.05-10mg/L Alcohol.
Reference: RBD-2351
HLK-LD2410C is a high-sensitivity 24GHz human presence status sensing module developed by Hi-Link Electronics. Its working principle is to use FMCW frequency-modulated continuous wave, to detect human targets in the set space, combined with radar signal processing, accurate human body induction algorithm, to achieve high sensitive human presence status...
Reference: RBD-0411
Low current consumption (typical 30 mA) CW or pulse operation Flat profile Long detection range (20 m) Supply voltage: 4.75V to 5.25V X-Band Frequency: 10.525 GHz Minimum Power Output: 13 dBm EIRP. RoboticsBD
Reference: RBD-0673
Detecting range: 300~10000ppm Signal output indicator. Dual Signal output (analog output and TTL output). The TTL output signal is low level, allows us to connect with SCM directly. Analog output 0~5V voltage. Quick response and recovery. RoboticsBD
Reference: RBD-2152
Human Presence Radar LD2410 Respiration and Heartbeat Monitoring Non-contact Induction Sensor High-sensitivity 24GHz sensing module
Reference: RBD-0427
Working voltage: 3.3V-5V Output form: digital output (0 and 1)
Reference: RBD-0674
Model: MQ-5 Operating Voltage: 5V DC Operating Temparature:-20~40 degree celcius
Reference: RBD-2227
High sensitivity 24GHz millimeter wave human presence detection radar module Detects and accumulates small movements like human breathing Higher accuracy in presence detection within a certain range Not easy to miss detections Detection distance: > 4m static human presence, > 16m motion Range: Hanging height 3m, static body detection coverage radius...
Reference: RBD-0664
Supply Voltage: 3.3 V/ 5V. Interface Type: I²C, SPI. Sensing Range: ±2g, ±4g, ±8g, ±16g. Sensitivity X: 28.6 LSB/g. Sensitivity Y: 31.2 LSB/g. Sensitivity Z: 34.5 LSB/g. Ultra Low Power: 40µA in measurement mode, 0.1µA in standby@ 2.5V. Free-Fall Detection. Tap/Double Tap Detection. RoboticsBD
Reference: RBD-0675
Model: MQ-6 Operating Voltage: 5V DC Detecting Range:200-10000 ppm Relative Humidity:<95% RH
Reference: RBD-2364
Pyroelectric Infrared Sensor Human Body Detecting PIR Motion Sensor Module for Arduino MCU 011050 Black Optical Lens
Reference: RBD-0676
Operating voltage: DC 5 V. The analog output voltage, the higher the concentration the higher the voltage. The carbon monoxide detection with better sensitivity. With a long service life and reliable stability. Rapid response and recovery characteristics. Range: 10 to 1000 ppm. RoboticsBD
Reference: RBD-0693
Operating Voltage: 3-5.5V Supply Current: ≥ 20mA Optimal Sensing Distance: 3mm Working voltage of 5V, the output of the black line low, white line of high output Uses Infrared Light to Detect Anti-Interference Ability Sensors to adopt TCRT5000 High Sensitivity, Stable Performance Exquisite workmanship, with the indicator Has a fixed bolt hole for easy...
Reference: RBD-2395
mmWave human presence sensor. It uses motion target tracking and can detect up to 3 people.
Reference: RBD-0677
Using high-quality dual-panel design, with power indicator and TTL signal output instructions. The switching signal having a DO (TTL) output and analog output AO. TTL output valid signal is low. The higher the voltage, the concentration of the analog output voltage is higher. A hydrogen gas detection with good sensitivity. Has a long life and reliable...
Reference: RBD-0822
S49E hall sensor Features wide-range voltage comparator LM393 Signal output indicator Analog / Digital output
Reference: RBd-2402
The 60GHz mmWave Multi-Human Sensing Radar Module Sensor can detect up to 8 people in its sensing area. The software is in Chinese, and it can report the position of people using a serial terminal.
Reference: RBD-0678
Good sensitivity to CO/Combustible Gas High sensitivity to Methane, Propane, and CO Long life and low cost Simple drive circuit Input voltage: DC 5±0.2V Current Consumption: 150mA
Reference: RBD-1192
Digital Output Hall-effect sensor. Operating voltage: typically 5V. Output Current: 25mA. It can be used to detect both the poles of a magnet.
Reference: RBD-2657
Compact and lightweight design for easy installation and operation, offering a plug-and-play experience. Automatically activates when detecting human body temperature within the sensing area in low-light environments, enabling automated control of connected lamps (with a 45-second time delay). Caution: Avoid using multiple lights in series or parallel and...
Reference: RBD-0679
Sensitivity to Ammonia, Sulfide and Benzene steam Sensitive for benzene, alcohol, smoke Fast response and recovery Adjustable sensitivity. RoboticsBD Signal output indicator Output voltage boosts along with the concentration of the measured gases increases.
Reference: RBD-1199
Low-noise output Fast power-on time Ratiometric rail-to-rail output 4.5 to 6.0 V operation Solid-state reliability Factory-programmed at end-of-line for optimumperformance Robust ESD performance
Reference: RBD-2722
Add computer vision capabilities to your project, without the coding! The Person Sensor includes a camera module pre-programed and connected over Qwiic... Person Sensor V1.1 by Useful Sensors
Reference: RBD-0812
Based on MAX30105 – heart rate, oximeter, smoke sensor Green, red, and infra-red LEDs Interface: I2C (address 0x57) Compatible with 3.3V and 5V logic levels.
Reference: RBD-1208
Working Voltage: 5V DC Operating Temperature: -30ºc ~ 85ºc Output high level when received the laser signal Output low level when not receive laser signal. Application: Electronic Circuits