
Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: RBD-0094
The Arduino Uno R3 High-Quality Edition Arduino UNO in Bangladesh Micro-controller : ATmega328. Operating Voltage : 5V. Input Voltage (recommended) : 7-12V. Digital I/O Pins : 14 (of which 6 provide PWM output). Analog Input Pins : 6. The Arduino Uno R3 High-Quality Edition embodies superior craftsmanship and meticulous attention to detail, resulting in...
If you want to detect methane gases with your projects, you will need sensors. If you need any data on the sensitive material then, the MQ-4 High Sensitivity Gas Methane (CNG) Detector Gas sensor Module is a quite good solution. RoboticsBD
This is a simple to use MQ-4 High Sensitivity Gas Methane (CNG) Detector Sensor Module which can sense the presence of Compressed Natural Gas(CNG), methane(CH4), etc in the air. The module uses our MQ-4 sensor. It simplifies the interface to the odd pin spacing of the sensor and provides the interface through standard 4 x 0.1″ header pins.
It provides an analog output corresponding to the concentration of the gases in the air and an easy-to-use digital output. The onboard potentiometer can be used to set the maximum gas concentration beyond which the digital output gets triggered. The MQ-4 can detect natural gas concentrations anywhere from 200 to 10000ppm. RoboticsBD
Just power the module with 5V set the threshold and you can start getting the gas concentration of the air around the sensor! An onboard LED signals the presence of any gas.
The digital output can be easily interfaced with microcontrollers and other circuits. The analog output can be hooked up to an ADC of a microcontroller to get a wide range of sensor readings. This is a simple-to-use compressed natural gas (CNG) sensor, suitable for sensing natural gas (composed of mostly Methane [CH4]) concentrations in the air. Featured By RoboticsBD.
Product Images are shown for illustrative purposes only and may differ from the actual product.
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
General Specification | |
Model | MQ-4 |
IC Chip | LM393 |
Operating Voltage (VDC) | 3 ~ 5 |
Detecting Range | 300ppm to 10000ppm |
Length (mm) | 31 |
Width (mm) | 19 |
Height (mm) | 21 |
Weight (gm) | 6 |
Shipment Weight | 0.01 kg |
Shipment Dimensions | 4 × 4 × 3 cm |
Please allow 5% measuring deviation due to manual measurement.
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
1 x MQ-4 High Sensitivity Gas Methane (CNG) Detector Sensor Module.
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
The latest price of MQ-4 Methane Natural Gas Sensor in Bangladesh is BDT 180 You can buy the MQ-4 Methane Natural Gas Sensor at best price from our RoboticsBD or visit RoboticsBD Office.
Please note that the product information provided on our website may not be entirely accurate as it is collected from various sources on the web. While we strive to provide the most up-to-date information possible, we cannot guarantee its accuracy. We recommend that you always read the product labels, warnings, and directions before using any product. |
Product Images are shown for illustrative purposes only and may differ from the actual product. |
Reference: RBD-0094
The Arduino Uno R3 High-Quality Edition Arduino UNO in Bangladesh Micro-controller : ATmega328. Operating Voltage : 5V. Input Voltage (recommended) : 7-12V. Digital I/O Pins : 14 (of which 6 provide PWM output). Analog Input Pins : 6. The Arduino Uno R3 High-Quality Edition embodies superior craftsmanship and meticulous attention to detail, resulting in...
Reference: RBD-0661
For Standard LCD 16x2 with Male Header. Press here For Standard LCD 16x2 with Female Header. Press here For Standard LCD 16x2 with I2C adapter board soldered. Press here. For Standard LCD 16x2 with White Background. Press here. For Standard LCD 16x2 with Blue Background. Press here.
Reference: RBD-0671
Operating Voltage:+5V Preheat Duration:20 s Analog Output Voltage:0 to 5 V Dimension:36x20x21 mm. RoboticsBD
Reference: RBD-0672
Power requirements: 5 VDC @ ~165 mA (heater on) / ~60 mA (heater off). Current Consumption: 150mA. RoboticsBD DO output: 0.1 and 5V. AO output: 0.1- 0.3 V (relative to pollution), the maximum concentration of a voltage of about 4V Detecting Concentration: 0.05-10mg/L Alcohol.
Reference: RBD-0674
Model: MQ-5 Operating Voltage: 5V DC Operating Temparature:-20~40 degree celcius
Reference: RBD-0675
Model: MQ-6 Operating Voltage: 5V DC Detecting Range:200-10000 ppm Relative Humidity:<95% RH
Reference: RBD-0676
Operating voltage: DC 5 V. The analog output voltage, the higher the concentration the higher the voltage. The carbon monoxide detection with better sensitivity. With a long service life and reliable stability. Rapid response and recovery characteristics. Range: 10 to 1000 ppm. RoboticsBD
Reference: RBD-0677
Using high-quality dual-panel design, with power indicator and TTL signal output instructions. The switching signal having a DO (TTL) output and analog output AO. TTL output valid signal is low. The higher the voltage, the concentration of the analog output voltage is higher. A hydrogen gas detection with good sensitivity. Has a long life and reliable...
Reference: RBD-0678
Good sensitivity to CO/Combustible Gas High sensitivity to Methane, Propane, and CO Long life and low cost Simple drive circuit Input voltage: DC 5±0.2V Current Consumption: 150mA
Reference: RBD-0679
Sensitivity to Ammonia, Sulfide and Benzene steam Sensitive for benzene, alcohol, smoke Fast response and recovery Adjustable sensitivity. RoboticsBD Signal output indicator Output voltage boosts along with the concentration of the measured gases increases.
Reference: RBD-0344
Output Sensitivity: 1.0 ± 0.1 mV / V. Two selectable differential input channels. On-chip active low noise PGA with the selectable gain of 32, 64 and 128. On-chip oscillator requiring no external component with optional external crystal. On-chip power-on-reset. Measurement Resolution: 24 bit. RoboticsBD
Reference: RBD-1206
Scanning Range: 18M Radius Detection Range: 12M Radius 4cm Ultra-thin Ideal for all kinds of service robot. 8000 times sample rate, the highest in the current economical LIDAR industry 360-degree laser range scanning Low Noise, Brushless Motor New Non-contact Drive OPTMAG Original Design, prolong the life-span Class 1 Laser Safety Standard High-speed...
Reference: RBD-1174
Low-noise analog signal path. Device bandwidth is set via the new FILTER pin. 5 µs output rise time in response to step input current. Small footprint, low-profile SOIC8 package. 2.1 kV RMS minimum isolation voltage from pins 1-4 to pins 5-8.
Reference: RBD-2289
Low cost, compact size dust sensor module Used to quantitative particle (> 1 micron) measurement Principle of particle counter Can sense the tobacco smoke and pollen, house dust Consist of light emitting diode lamp, detector, signal amplifier circuit and heater Used in applications such as the air cleaner or air purifier Users can use this sensor...
Reference: RBD-1946
Comes with the BME280 sensor. Pressure accuracy of ±1 hPa. Temperature accuracy ±1.0°C. Altimeter accuracy ±1 meter. Humidity: +-3%
Reference: RBD-1856
Dual channel stereo, high output power (3 w + 3 w power @ 5V and 4 ohms load).. Double panel wiring solves crosstalk. Super mini design allows it to be easily placed in a variety of digital products. 3W Output at 10% THD with a 4ΩLoad and 5V Power Supply. Filterless, Low Quiescent Current and Low EMI and Low Noise. Short Circuit Protection and Thermal...
Reference: RBD-0812
Based on MAX30105 – heart rate, oximeter, smoke sensor Green, red, and infra-red LEDs Interface: I2C (address 0x57) Compatible with 3.3V and 5V logic levels.
Reference: RBD-1854
This module is compatible with various microcontroller control boards, such as arduino series microcontrollers. The module contains 2 kinds of interfaces. The module comes with a 20cm wire, which is long enough for your use. It has a short response time and quick response.
Reference: RBD-2080
Clean, good waveform driving ability, more than 15mA. Working voltage 3.3V-5 Output format: digital switching output (0 and 1) A fixed bolt holes for easy installation
Reference: RBD-1716
Working Voltage: 5.0V Maximum Working Current: 100mA Data Interface Level: L<0.8V, H>2.7V, maximum voltage level 3.3V Particle Measurement Range: 0.3 ~ 1.0μm; 1.0 ~ 2.5μm; 2.5 ~ 10μm
Reference: RBD-2139
GSR Skin Sensor CJMCU-6701 Analog SPI Module Measures the electrical conductance of the skin (Galvanic Skin Response) Reflects human emotional activity and stress levels Suitable for creating emotion-related projects and sleep quality monitors Utilizes a precise 12-bit AD converter for accurate readings
Reference: RBD-1195
Temperature Coefficient Type: NTC Thermal Time Constant: 10s Resistance 10kΩ Tolerance: ±1%
Reference: RBD-0355
Description:Working voltage: 4.5V to 5.5 V.Transmit tube pressure drop: Vf = 1.6 VTransmit tube current: 20 mASignal output: A, B two way; The TTL levelDistinguish precision: 0.01 mmMeasurement frequency, 100 KHZEncoder diameter: 24 mmEncoder type D hole diameter: 4 mmThe encoder resolution: 20 line
Reference: RBD-1857
Output: NPN Model KT-RG22 Coaxial reflection type Supply voltage DC10-30V±10% Can be used in all kinds of machines
Reference: RBD-2300
This product has stable performance, high sensitivity, fast response, stable output, and is suitable for various soil qualities . It is an important tool for observing and studying the occurrence, evolution, improvement and water-salt dynamics of saline soil. By measuring the dielectric constant of soil, it can directly and stably reflect the real...
Reference: RBD-0337
Brand: Waveshare
Detection depth: 48mm Power: 2.0V ~ 5.0V Dimension: 19.0mm * 63.0mm Mounting holes size: 2.0mm
Reference: RBD-2482
Module utilizes the popular 1-Wire DS18B20 temperature measurement IC.
Reference: RBD-1201
Measurement range: 12 m. Operating Voltage: 5V. Power : 0.12w. Weight: 6 gm. Compatible with Pixhawk Controller. Frequency: 100Hz
Reference: RBD-1177
This signal generator can use 4-20mA to generate voltage and control the current in the circuit. Accuracy up to 0.01; Liquid crystal display; Rotary encoder adjustment ; Two connection terminals are non polarity. Output range can be set; 4-20mA (device control) / -21mA (signal debugging) Display mode can be set, it is convenient for you to see the value...
Reference: RBD-2420
Detection distance: 2-40cm IO Interface: 4-wire interfaces (- / + / S / EN) Output signal: TTL level Adjustment: adjust multi-turn resistance Effective angle: 35 °
Reference: RBD-1178
Size: 5mm Emitted Color : UV View Angle: About 20 - 25 degree. Luminous Intensity: 800mcd-2500mcd
Reference: RBD-2351
HLK-LD2410C is a high-sensitivity 24GHz human presence status sensing module developed by Hi-Link Electronics. Its working principle is to use FMCW frequency-modulated continuous wave, to detect human targets in the set space, combined with radar signal processing, accurate human body induction algorithm, to achieve high sensitive human presence status...
Reference: RBD-1753
Digital I2S interface with high precision 24-bit data High signal to noise ratio is 61 dBA High sensitivity – 26 dBFS Stable frequency response from 60 Hz to 15 kHz Low power consumption: low current consumption 1.4 mA High PSR: -75 dBFS
Reference: RBD-1377
Module Name:CJMCU-4541 Sensor: MICS-4514 Type: Carbon Monoxide Nitrogen Oxygen Sensor
Reference: RBD-2091
Digital signal output 18B20 Temperature Sensor Chip (MY18E20 or DS18b20) Resolution adjustment ranges from 9-12 bytes. Send data via a pin Temperature measurement ranges: -55°C to +125°C, be accurate to 0.5°C.Compatible with DS18B20
Reference: RBD-0686
Supply voltage 5-30VDC Detection distance 10mm (effective detection distance 0-10mm) Load current 150MA (no more than) Output form NPN three lines
Reference: RBD-1204
Distance measuring range: 100 cm to 550 cm Output type: Analog voltage Output voltage differential over distance range: 2.05 V (typical) Update period: 38 ± 10 ms
Reference: RBD-2097
5V Dc Power Supply Power indicator light The comparator output is light High Sensitivity Sound Microphone Sensor Detection Module Electric condenser microphone
Reference: RBD-2092
Product Type: LED Shape: Round LED 5mm DIP type Color: pink yellow-green (high brightness) Lens type: white mist Standard Forward Voltage:3.0-4 .5 V
Reference: RBD-2132
GSR Galvanic Skin Response Module for measuring skin resistance and conductivity Size: 34mm x 25mm Power interface pin for easy connectivity Working current: 1mA Power voltage: 3.3-5V
Reference: RBD-0983
Capacity (mAh): 960-2000 Output Voltage: 3.7V High energy density High working voltage for single battery cells. Pollution-free Long cycle life SMALL SUN
Reference: RBD-2105
40P color jumper wires Length: 300mm Weight: 45 gm Compatible with 2.54mm spacing pin headers High quality and in good working condition Durable and reusable Easy to install and use
Reference: RBD-0992
Resistance: 10k Ohm Tolerance: 10 % Temperature coefficient: ±100 ppm/ºC Operating temperature range: -55ºC to +125ºC Mounting type: Through-hole
Reference: RBD-2144
Automatic induction: to enter the sensing range Ultra-small size. Repeatable trigger Wide operating voltage range Micropower: quiescent current <50 Output high signal: easy docking and all kinds of circuits.
Reference: RBD-1925
Use for convert battery with Deans to XT60 on ESC / charger. Excellent performance, solid and secure connection, safety in use. High quality and compact,easily to add the adapter. No wires design can save more space.
Reference: RBD-1319
High Quality Extra power Rechargeable Must be Charged after purchase Constant 9V Output till lasts Metal Jacket Body Good Built Quality and hence Leakproof Easy to install and Replace Corrosion free Connector Point for long-term use 0% Mercury and Cadmium. Environment-friendly OEM Compatible. *** New Batteries must be charged before use.
Reference: RBD-1020
Frequency (MHz) : 824 – 960 MHz & 1710 – 1980 MHz Gain:2 / 3 dBi Impedance (Ω): 50 Connector Type: SMA Plug VSWR :< 2.5
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...