Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: 1353
Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Display Voltage and current simultaneously in different colors, red for Voltage and blue for current (the current is Measured in the negative rail). 2 Require external power supply; with reversed connection protection. 3 Ground wire of testing end and power supply terminal is the same wire; quick refresh of about 500 MS/time. 4 With built-in shunt, has Voltage and current calibration potentiometers. Applications: Suitable for automotive/electric cars/motorcycles battery monitoring or other product’s voltage current measurement
Features:
1 x Dual Led 0.28 ” Red Blue Display for DC.0-100V 100A Voltage and Current Test Digital Instrument.
The latest price of DC 0-100V 100A Voltage and Current Dual LED Display Panel Meter in Bangladesh is BDT 350 You can buy the DC 0-100V 100A Voltage and Current Dual LED Display Panel Meter at best price from our RoboticsBD or visit RoboticsBD Office.
Please note that the product information provided on our website may not be entirely accurate as it is collected from various sources on the web. While we strive to provide the most up-to-date information possible, we cannot guarantee its accuracy. We recommend that you always read the product labels, warnings, and directions before using any product. |
Product Images are shown for illustrative purposes only and may differ from the actual product. |
Reference: RBD-2224
Voltage – 250V Easy PCB mounting Good consistency Widely acclaimed
Reference: RBD-1835
Input current (RMS): 50A. Work temperature: -25℃~+70℃. Storage temperature: -30℃~+90℃. Work voltage: 660V. Frequency range: 50Hz-1KHz.
Reference: RBD-1174
Low-noise analog signal path. Device bandwidth is set via the new FILTER pin. 5 µs output rise time in response to step input current. Small footprint, low-profile SOIC8 package. 2.1 kV RMS minimum isolation voltage from pins 1-4 to pins 5-8.
Reference: RBD-2342
INA3221 3 Channel Shunt Current Voltage Monitor Sensor, high-side current and bus voltage monitor with an I2C- and SMBUS-compatible interface
Reference: RBD-0562
Input Voltage: DC3.6V-6V Input Current: 2A-5A Output Voltage: DC 400KV (Please pay attention to safety when used) Input Line Length: about 100mm (red is positive) Output Line Length: about 160mm
Reference: RBD-1675
Model: PZEM-004T Operating Voltage: 80-260VAC Test Voltage: 80-260VAC Rated Current: 100A Rated power: 100A / 22000W Operating frequency: 45-65Hz Measurement accuracy: 1.0
Reference: RBD-2653
2.8V-5.5V to ±12V DC Conversion Step Up Power Supply Module is straightforward. There is a 2.8 to 5.5 V DC input and the module outputs +12 V and -12 V DC dual power supply voltage with a current rating of a maximum 30 mA. Off course the current output is low but sometimes it suits in many situations where one is looking forward for a small boost...
Reference: RBD-2346
HW-671 WCS1800 Hall Current Sensor Over-current Protection Module Detection
Reference: RBD-0559
Power supply: DC 7-30 V Input Voltage: 0-10V Output current: 4-20mA 0-5V to 4-20mA Linear Conversion
Reference: RBD-1972
Brand: DFRobot
Brand Gravity Analog AC Current Sensor 20A AC Current Signal Conversion Module Open Type AC Transformer Probe Included Non-contact Measurement
Reference: RBD-1344
Supply voltage range: DC 7 V ~ 35 V Output voltage signal: 0 ~ 2.5 v, 3.3 v, 5 v, 10 v, 15 V. 4-20mA to 0-15V,0-5V,0-10V
Reference: RBD-2735
Measures high-side current and voltage up to 3.2A @ 26VDC.
Reference: RBD-1424
Onboard precision microcurrent transformer. Onboard sampling resistor. The module can measure AC currents less than 5A, the corresponding analog output 5A/5mA. Rated input current: 5A Rated output current: 5mA Change: 1000: 1 The linear range: 0 ~ 10A (100 ohms) Linearity: 0.2%
Reference: RBD-2073
Digital Output Hall-effect sensor. Operating voltage: typically 5V. Output Current: 25mA. It can be used to detect both the poles of a magnet.
Reference: RBD-2361
Working voltage: 3V-5V (MAN SV) Static output voltage: VCCi2 Working current: 135m2A (MAX) Small in size, with easy mounting capability. Monolithic Hall IC for high reliability
Reference: RBD-1173
Input Current : 100A Frequency: 50HZ-150KHZ Opening Size: 13 x 13mm/ 0.5″ x 0.5″(L*W) Output Plug 3.5mm Dielectric Strength 6000V AC/1min Meet UL94-V0 flame retardant properties
Reference: RBD-0564
Onboard precision microcurrent transformer. Onboard sampling resistor. The module can measure AC currents less than 5A, the corresponding analog output 5A/5mA. Rated input current: 5A Rated output current: 5mA Change: 1000: 1 The linear range: 0 ~ 10A (100 ohms) Linearity: 0.2%
Reference: RBD-1175
Low-noise analog signal path Device bandwidth is set via the new FILTER pin 5 µs output rise time in response to step input current Small footprint, low-profile SOIC8 package 2.1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8 Supply Voltage: 4.5V~5.5V DC Measure Current Range: 20A Sensitivity: 100mV/A
Reference: RBD-2677
Operating on a 5V DC power supply with a current consumption of less than 60mA, this 0.28-inch Digital Voltmeter Ammeter is a versatile tool for measuring voltage and current. With a testing range of 0-100V for voltage and 1-100A for current, this meter offers precise measurements with easy readability, even in dim light conditions.
Reference: RBD-2704
Convert voltage signals (0-5V) to industry-standard current signals (4-20mA) for control systems. Isolated design ensures safe operation and minimizes electrical noise interference. Wide operating voltage range (12-24V) for compatibility with various power supplies. Easy to use with clear LED indicators and simple connections.
Reference: RBD-2120
Onboard precision microcurrent transformer. Onboard sampling resistor. The module can measure AC currents less than 5A, the corresponding analog output 5A/5mA.
Reference: RBD-0555
Low-noise analog signal path Device bandwidth is set via the new FILTER pin 5 µs output rise time in response to step input current Small footprint, low-profile SOIC8 package 2.1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8 Supply Voltage: 4.5V~5.5V DC Measure Current Range: 30A Sensitivity: 100mV/A
Reference: RBD-1177
This signal generator can use 4-20mA to generate voltage and control the current in the circuit. Accuracy up to 0.01; Liquid crystal display; Rotary encoder adjustment ; Two connection terminals are non polarity. Output range can be set; 4-20mA (device control) / -21mA (signal debugging) Display mode can be set, it is convenient for you to see the value...
Reference: RBD-2072
Operating Voltage: 3.3V-5V Features wide range voltage comparator LM393 Adjustable sensitivity Signal output indicator with the retaining bolt hole, convenient installation Output form digital switch output (0 and 1 high and low level) The output effective signal is low level When there is sound, outputs low level and the signal light
Reference: RBD-1836
Input Current : 0-30A Output Mode: 0-1V @ 30mA Frequency: 50HZ-150KHZ Opening Size: 13 x 13mm/ 0.5″ x 0.5″(L*W) Output Plug 3.5mm Dielectric Strength 6000V AC/1min Suitable for lighting equipment, AC motors, air compressors, monitoring, current measurement, and protection Meet UL94-V0 flame retardant properties
Reference: RBD-2748
A voltage detector is handy for projects where you want to make sure your microcontroller doesn't run at a low voltage. For example, say you have a Feather Huzzah running on a lipoly battery every few minutes. Eventually, the battery runs down and goes below 3.3V, so the voltage to the ESP8266 core is too low, and could cause a lockup or corrupted data....
Reference: RBD-2071
Type: Magnetic Sensor Module Mainly Compatible with: Ardunio
Reference: RBD-2675
You can also use the IICLCD1602 LCD to display voltage. By 3P connector, connect this module with the expansion of board Arduino Voltage input range: DC 0-25 V Voltage detection range: DC 0.02445 V to 25 V Voltage analog resolution : 0.00489 V
Reference: RBD-1764
High Power DC-DC Step Down Module Input Voltage: 5-40V DC Output Voltage: 1.2-36V DC Efficiency: 95% Maximum Power: 200W
Reference: RBD-2276
Versatile adjustable resistor with precise control and compact size. Cost-effective potentiometer with 5K resistance and single turn. Trimmer potentiometer with yellow casing for easy identification. Commonly used in audio, lighting, and temperature control circuits. Through-hole mounting potentiometer for easy circuit integration.
Reference: RBD-1444
IC Name: S8050 Bipolar Transistor Package/Case: DIP-3
Reference: RBD-0247
Resistance: 330 Ohm Tolerance: 5% Max. Working Voltage: 250V Temperature Coefficient of Resistance: 50PPM/°C
Reference: RBD-2453
Fully self contained panel meter with dual red and blue display.