- New
Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: 1353
Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
If you want to make a project with carbon dioxide sensors also need a good range sensing property on this sensor then this module is good for you. This sensor measures gaseous carbon dioxide levels by monitoring the amount of infrared (IR) radiation absorbed by carbon dioxide molecules. This type of sensor is used in monitoring indoor air quality, landfills, process control, and controlled environment horticulture.
MG-811 Carbon Dioxide Sensor Module (Carbon dioxide sensor) is a carbon dioxide sensor (CO2) sensor that is a Metal Oxide Sensor sensor, which must heat the tank to the specified level. (With the method of supplying power) will cause heat vapor and separate CO2 from the air. This sensor module has an MG-811 onboard as the sensor component. A signal output circuit for heating the sensor The MG-811 is highly sensitive to CO2 and less sensitive to alcohol and CO. The output voltage of the CO2 increases.
Useful for greenhouses and medical projects. Sends an analog signal that decreases as the concentration of CO2 increases. This module also includes a digital output pin with TTL output. The Potentiometer on board is used to set the Digital Output Setpoint. After setting the potentiometer threshold, once that threshold is reached, an LED on the sensor will illuminate and the digital pin will give a HIGH voltage signal. Featured By RoboticsBD.
Product Images are shown for illustrative purposes only and may differ from the actual product.
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
General Specification | |
Model | MG811 |
Operating Voltage (V) | 6V DC |
Characteristic Gas | CO2 |
Detection Zone | 0 – 10000 ppm |
Length (mm): | 32 |
Width (mm): | 22 |
Height (mm): | 29 |
Weight (g): | 10 |
Shipping Weight | 0.015 kg |
Shipping Dimensions | 4 × 3 × 4 cm |
Please allow 5% measuring deviation due to manual measurement.
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
1 x MG811 (Co2) Carbon Dioxide Gas Sensor
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD RoboticsBD
The latest price of MG811 (Co2) Carbon Dioxide Gas Sensor in Bangladesh is BDT 2,485 You can buy the MG811 (Co2) Carbon Dioxide Gas Sensor at best price from our RoboticsBD or visit RoboticsBD Office.
Please note that the product information provided on our website may not be entirely accurate as it is collected from various sources on the web. While we strive to provide the most up-to-date information possible, we cannot guarantee its accuracy. We recommend that you always read the product labels, warnings, and directions before using any product. |
Product Images are shown for illustrative purposes only and may differ from the actual product. |
Reference: RBD-0671
Operating Voltage:+5V Preheat Duration:20 s Analog Output Voltage:0 to 5 V Dimension:36x20x21 mm. RoboticsBD
Reference: RBD-0672
Power requirements: 5 VDC @ ~165 mA (heater on) / ~60 mA (heater off). Current Consumption: 150mA. RoboticsBD DO output: 0.1 and 5V. AO output: 0.1- 0.3 V (relative to pollution), the maximum concentration of a voltage of about 4V Detecting Concentration: 0.05-10mg/L Alcohol.
Reference: RBD-0673
Detecting range: 300~10000ppm Signal output indicator. Dual Signal output (analog output and TTL output). The TTL output signal is low level, allows us to connect with SCM directly. Analog output 0~5V voltage. Quick response and recovery. RoboticsBD
Reference: RBD-0674
Model: MQ-5 Operating Voltage: 5V DC Operating Temparature:-20~40 degree celcius
Reference: RBD-0675
Model: MQ-6 Operating Voltage: 5V DC Detecting Range:200-10000 ppm Relative Humidity:<95% RH
Reference: RBD-0676
Operating voltage: DC 5 V. The analog output voltage, the higher the concentration the higher the voltage. The carbon monoxide detection with better sensitivity. With a long service life and reliable stability. Rapid response and recovery characteristics. Range: 10 to 1000 ppm. RoboticsBD
Reference: RBD-0677
Using high-quality dual-panel design, with power indicator and TTL signal output instructions. The switching signal having a DO (TTL) output and analog output AO. TTL output valid signal is low. The higher the voltage, the concentration of the analog output voltage is higher. A hydrogen gas detection with good sensitivity. Has a long life and reliable...
Reference: RBD-0678
Good sensitivity to CO/Combustible Gas High sensitivity to Methane, Propane, and CO Long life and low cost Simple drive circuit Input voltage: DC 5±0.2V Current Consumption: 150mA
Reference: RBD-0679
Sensitivity to Ammonia, Sulfide and Benzene steam Sensitive for benzene, alcohol, smoke Fast response and recovery Adjustable sensitivity. RoboticsBD Signal output indicator Output voltage boosts along with the concentration of the measured gases increases.
Reference: RBD-1654
5 In 1 Portable CO2 Detector Air Quality Detector Intelligent Air Detector Temperature and Humidity Sensor Carbon Dioxide Monitor TVOC Formaldehyde Detection HCHO Detector Color Black
Reference: RBD-1934
Dual signal output (analog output and TTL level output) The TTL output effective signal is low. Analog output 0 ~ 5V voltage, the higher the concentration the higher the voltage. Good sensitivity to hydrogen sulfide, liquefied gas, natural gas, city gas, and smoke. with long service life and reliable stability fast response recovery characteristics
Reference: RBD-2075
MQ-2 Smoke Gas Detector Sensor ME084 Module for Arduino Operating Voltage:+5V Preheat Duration:20 s
Reference: RBD-2508
The ENS160 is a digital multi-gas sensor specifically designed for indoor air quality testing that optimizes the detection of a wide variety of gases and volatile organic compounds (VOCS), including toluene, hydrogen, ethanol, N02 and ozone. The air quality sensor is used in home and building automation, consumer products, electrical and air purification
Reference: RBD-2550
This multi-functional air quality monitor offers simultaneous testing for PM2.5, CO2, TVOC, HCHO, AQI, temperature, and humidity. Featuring a 2.8-inch TFT color display, it provides clear and easy-to-read detection data. Additionally, the monitor can be connected to the Tuya App for real-time air quality monitoring and historical data trend analysis...
Reference: RBD-1751
Detection Gas: H2, Alcohol, CO, VOC Detection Range: 10~500ppmH2 5~500ppm Alcohol 10~500ppm CO Air Quality Sensor Module
Reference: RBD-1654
5 In 1 Portable CO2 Detector Air Quality Detector Intelligent Air Detector Temperature and Humidity Sensor Carbon Dioxide Monitor TVOC Formaldehyde Detection HCHO Detector Color Black
Reference: RBD-0677
Using high-quality dual-panel design, with power indicator and TTL signal output instructions. The switching signal having a DO (TTL) output and analog output AO. TTL output valid signal is low. The higher the voltage, the concentration of the analog output voltage is higher. A hydrogen gas detection with good sensitivity. Has a long life and reliable...
Reference: RBD-1966
Tuya Smart Wifi Wireless Natural Gas Leak Detector Gas Sensor Household Combustible LPG Gas Leak Alarm Detector With LCD Display
Reference: RBD-0672
Power requirements: 5 VDC @ ~165 mA (heater on) / ~60 mA (heater off). Current Consumption: 150mA. RoboticsBD DO output: 0.1 and 5V. AO output: 0.1- 0.3 V (relative to pollution), the maximum concentration of a voltage of about 4V Detecting Concentration: 0.05-10mg/L Alcohol.
Reference: RBD-0671
Operating Voltage:+5V Preheat Duration:20 s Analog Output Voltage:0 to 5 V Dimension:36x20x21 mm. RoboticsBD
Reference: RBD-0673
Detecting range: 300~10000ppm Signal output indicator. Dual Signal output (analog output and TTL output). The TTL output signal is low level, allows us to connect with SCM directly. Analog output 0~5V voltage. Quick response and recovery. RoboticsBD
Reference: RBD-1719
Envitec Honeywell OOM202 Medical Ventilator Oxygen Sensor Made in GermanyManufacture Date: 2023 December
Reference: RBD-0676
Operating voltage: DC 5 V. The analog output voltage, the higher the concentration the higher the voltage. The carbon monoxide detection with better sensitivity. With a long service life and reliable stability. Rapid response and recovery characteristics. Range: 10 to 1000 ppm. RoboticsBD
Reference: RBD-1716
Working Voltage: 5.0V Maximum Working Current: 100mA Data Interface Level: L<0.8V, H>2.7V, maximum voltage level 3.3V Particle Measurement Range: 0.3 ~ 1.0μm; 1.0 ~ 2.5μm; 2.5 ~ 10μm Note: Please purchase this adapter board to use it with Arduino and Raspberry Pi.
Reference: RBD-1640
Color: White Material: Metal + Plastic Operating Voltage : 12V DC Standby Current : ≤90mA Alarm Current : ≤100mA
Reference: RBD-2075
MQ-2 Smoke Gas Detector Sensor ME084 Module for Arduino Operating Voltage:+5V Preheat Duration:20 s
Reference: RBD-0674
Model: MQ-5 Operating Voltage: 5V DC Operating Temparature:-20~40 degree celcius
Reference: RBD-0678
Good sensitivity to CO/Combustible Gas High sensitivity to Methane, Propane, and CO Long life and low cost Simple drive circuit Input voltage: DC 5±0.2V Current Consumption: 150mA
Reference: RBD-0812
Based on MAX30105 – heart rate, oximeter, smoke sensor Green, red, and infra-red LEDs Interface: I2C (address 0x57) Compatible with 3.3V and 5V logic levels.
Reference: RBD-1934
Dual signal output (analog output and TTL level output) The TTL output effective signal is low. Analog output 0 ~ 5V voltage, the higher the concentration the higher the voltage. Good sensitivity to hydrogen sulfide, liquefied gas, natural gas, city gas, and smoke. with long service life and reliable stability fast response recovery characteristics
Reference: RBD-0679
Sensitivity to Ammonia, Sulfide and Benzene steam Sensitive for benzene, alcohol, smoke Fast response and recovery Adjustable sensitivity. RoboticsBD Signal output indicator Output voltage boosts along with the concentration of the measured gases increases.
Reference: RBD-0675
Model: MQ-6 Operating Voltage: 5V DC Detecting Range:200-10000 ppm Relative Humidity:<95% RH
Reference: RBD-0431
Working temperature : -10℃ ~ 50℃ Working humidity : below saturation point Storage temperature : -20℃ ~ 80℃ RoboticsBD
Reference: RBD-1377
Module Name:CJMCU-4541 Sensor: MICS-4514 Type: Carbon Monoxide Nitrogen Oxygen Sensor
Reference: RBD-2325
Brand: DFRobot
This is a dissolved oxygen sensor kit. A dissolved oxygen meter is used to measure the dissolved oxygen in water, to reflect the water quality. It is widely applied in many water quality applications, such as aquaculture, environment monitoring, natural science, etc. There’s an old saying regarding keeping fish, “Good fish deserves good water”. Good...
Reference: RBD-2497
Compact size, measuring only 13*13*2.5mm Low power consumption High sensitivity and rapid response recovery Advanced MEMS technology Gas detected: CO Sensitivity: R0(in air) / Rs(in 150ppm CO) ≥ 3 Lifespan: ≥5 years (in air)
Reference: RBD-0958
Five Operating Modes Integrated MCU Onboard Processing Standard I2C Digital Interface Optimized Low-Power Modes Optional NTC Thermistor Pins
Reference: RBD-2508
The ENS160 is a digital multi-gas sensor specifically designed for indoor air quality testing that optimizes the detection of a wide variety of gases and volatile organic compounds (VOCS), including toluene, hydrogen, ethanol, N02 and ozone. The air quality sensor is used in home and building automation, consumer products, electrical and air purification