Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: 1353
Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Selecting the most reliable sensor for any Application is quite tricky as you need to think over various specs like its size, accuracy, operating specifications, and most importantly, its price. Here, we carry around 150+ differential sensors with all technical specifications and its application guidelines to narrow down your search filters which gives the highest level of satisfaction to you. Explore a wide range of best-picked sensors by Robotics Bangladesh from top brands at sensible prices in Bangladesh.
Subcategories
Reference: RBD-0041
Bases at CSR BC04 Bluetooth technology. with build-in 2.4GHz PCB antenna It’s at the Bluetooth class 2 power level. Range test: 10 meters Operating voltage: 3.3V to 6V DC Operating current in pairing is in the range of 30~40mA.
Reference: RBD-0169
Flex length: 5.6 cm. Total Length: 2.2″ (7 cm). Life Cycle : >1 million. Height : 0.43mm (0.017″), Flat Resistance: 10K Ohms ±30%. Power Rating: 0.5 Watts.
Reference: RBD-0291
Main chip: LM393, Electret condenser microphone Working voltage: DC 3.3-5V Induction distance is 0.5M Signal output Indication Single channel signal output The output effective signal is low level.
Reference: RBD-0431
Working temperature : -10℃ ~ 50℃ Working humidity : below saturation point Storage temperature : -20℃ ~ 80℃ RoboticsBD
Reference: RBD-0311
Working Voltage: 5 to 18V DC (min tested working voltage 4.5V). RoboticsBD Max current draw: 15mA @ 5V. Working Flow Rate: 1 to 30 Liters/Minute. Maximum water pressure: 2.0 MPa. Flow rate pulse characteristics: Frequency (Hz) = 7.5 * Flow rate (L/min). RoboticsBD
Reference: RBD-0368
Thickness: 0.4mm Trigger Force: 20g, triggered (default resistance<200kΩ) Pressure Measuring Range: 20g~6kg Static Pressure & Dynamic Pressure Measurement (within the frequency of 10Hz) Initial Resistance: >10MΩ Activation Time: <0.01S Operating Temperature: -40°C~+85°C Lifespan: >1million times Hysteresis: +10%,(RF+ -RF-)/FR+,1000g...
Reference: RBD-0550
Supply Voltage: 4.5 – 5.5 V. Current : <40 mA. Digital Interface : 5V TTL level for UART interface and GPIO. Support maximum 80 voice commands, with each voice 1500ms (one or two words speaking). Maximum 7 voice commands effective at same time. Arduino library is supplied. User-control General Pin Output. RoboticsBD
Reference: RBD-0671
Operating Voltage:+5V Preheat Duration:20 s Analog Output Voltage:0 to 5 V Dimension:36x20x21 mm. RoboticsBD
Reference: RBD-0355
Description:Working voltage: 4.5V to 5.5 V.Transmit tube pressure drop: Vf = 1.6 VTransmit tube current: 20 mASignal output: A, B two way; The TTL levelDistinguish precision: 0.01 mmMeasurement frequency, 100 KHZEncoder diameter: 24 mmEncoder type D hole diameter: 4 mmThe encoder resolution: 20 line
Reference: RBD-0417
Easily customizable to a wide range of sizes Cost-effective Ultra-thin; 0.45 mm Robust; up to 10 million actuations Simple and easy to Integrate. RoboticsBD
Reference: RBD-0672
Power requirements: 5 VDC @ ~165 mA (heater on) / ~60 mA (heater off). Current Consumption: 150mA. RoboticsBD DO output: 0.1 and 5V. AO output: 0.1- 0.3 V (relative to pollution), the maximum concentration of a voltage of about 4V Detecting Concentration: 0.05-10mg/L Alcohol.
Reference: RBD-0690
The main chip: ISD1820. Operating Voltage: DC 3V-5V. Loudspeaker: 8Ω, 0.5W. An easy to use 10 seconds of voice recording. High-quality, natural voice restored. Can be used as a propaganda module. With looping, jog playback, single-pass play function.
Reference: RBD-0411
Low current consumption (typical 30 mA) CW or pulse operation Flat profile Long detection range (20 m) Supply voltage: 4.75V to 5.25V X-Band Frequency: 10.525 GHz Minimum Power Output: 13 dBm EIRP. RoboticsBD
Reference: RBD-0552
Working frequency: quad-band network, 850 / 900 / 1800 / 1900MHz Working voltage: 4.8-9VDC(On-board voltage regulator circuit supply power for A6 module) Working Current: maximum of 2A. RoboticsBD
Reference: RBD-0673
Detecting range: 300~10000ppm Signal output indicator. Dual Signal output (analog output and TTL output). The TTL output signal is low level, allows us to connect with SCM directly. Analog output 0~5V voltage. Quick response and recovery. RoboticsBD
Reference: RBD-1022
Main chip: LM393, Electret condenser microphone Working voltage: DC 3.3-5V Induction distance is 0.5M Signal output Indication Single channel signal output The output effective signal is low level.
Reference: RBD-0427
Working voltage: 3.3V-5V Output form: digital output (0 and 1)
Reference: RBD-0663
Power supply voltage(VCC): 2.0, 3, 5.5 V. Output high VOH: 0.8VCC V Output low VOL: 0.3VCC V Response time (touch mode) : 60 mS Response time (low power mode) : 220 mS Can replace the traditional touch of a button Four M2 screws positioning holes for easy installation RoboticsBD
Reference: RBD-0674
Model: MQ-5 Operating Voltage: 5V DC Operating Temparature:-20~40 degree celcius
Reference: RBD-1324
Operating voltage: 2.5V-5.5V Maximum output power: 3W x 2 PCB size is about: length 30mm width 22mm overall height after installed is about 16mm Built with switch Potentiometer, can adjust the volume & control power switch freely! Flexible assembly usage.
Reference: RBD-0664
Supply Voltage: 3.3 V/ 5V. Interface Type: I²C, SPI. Sensing Range: ±2g, ±4g, ±8g, ±16g. Sensitivity X: 28.6 LSB/g. Sensitivity Y: 31.2 LSB/g. Sensitivity Z: 34.5 LSB/g. Ultra Low Power: 40µA in measurement mode, 0.1µA in standby@ 2.5V. Free-Fall Detection. Tap/Double Tap Detection. RoboticsBD
Reference: RBD-0675
Model: MQ-6 Operating Voltage: 5V DC Detecting Range:200-10000 ppm Relative Humidity:<95% RH
Reference: RBD-0700
Operating Voltage: 3.3V-5.5V Low Power Consumption High Accuracy Small Size
Reference: RBD-1738
Operating Voltage : 1.5 ~ 15V DC Working Current: Less than 25mA Tone Generation Range : 1.5 ~ 2.5kHz Dimensions (LxWxH): 26 x 15 x 11 mm
Reference: RBD-0676
Operating voltage: DC 5 V. The analog output voltage, the higher the concentration the higher the voltage. The carbon monoxide detection with better sensitivity. With a long service life and reliable stability. Rapid response and recovery characteristics. Range: 10 to 1000 ppm. RoboticsBD
Reference: RBD-0693
Operating Voltage: 3-5.5V Supply Current: ≥ 20mA Optimal Sensing Distance: 3mm Working voltage of 5V, the output of the black line low, white line of high output Uses Infrared Light to Detect Anti-Interference Ability Sensors to adopt TCRT5000 High Sensitivity, Stable Performance Exquisite workmanship, with the indicator Has a fixed bolt hole for easy...
Reference: RBD-0982
Model: HX710B Data Output Rate:10 SPS / 80SPS Max. Operating Current (mA):1.5 IC Package:16 Pin SOP
Reference: RBD-1753
Digital I2S interface with high precision 24-bit dataHigh signal to noise ratio is 61 dBAHigh sensitivity – 26 dBFSStable frequency response from 60 Hz to 15 kHzLow power consumption: low current consumption 1.4 mAHigh PSR: -75 dBFS
Reference: RBD-0677
Using high-quality dual-panel design, with power indicator and TTL signal output instructions. The switching signal having a DO (TTL) output and analog output AO. TTL output valid signal is low. The higher the voltage, the concentration of the analog output voltage is higher. A hydrogen gas detection with good sensitivity. Has a long life and reliable...
Reference: RBD-0822
S49E hall sensor Features wide-range voltage comparator LM393 Signal output indicator Analog / Digital output
Reference: RBD-1018
Dimensions: 75 x 13 x 13 mm (L x W x H) Range: 5 kg Cable Length: 18 cm Fitting ScrewHole Size: M3 Rated output: 1.0 0.1mV / V Nonlinear: 0.05% F.S Hysteresis: 0.0% F.S Repeatability: 0.05% F.S
Reference: RBD-1773
Supply Voltage: 5V USB / 3.7V lithium battery Output Port: 3-wire audio interface/DIY pad Output Type: Analog signal Bluetooth name: VHM-314-V3.0 Bluetooth version: 5.0 Bluetooth passcode: no password Sound source: Bluetooth. USB-PC input(after the back pad is connected, the computer can be connected as a sound card though Micro) Operation method:...