• How to Place an Order

  • Store Pick Up

  • Request for Quotation/ International Sourcing

  • Order Status

Choose Your Size Quick view

Reference: 984

Heat Shrink Tube

Heat Shrink Tubing 2:1, Eventronic Electrical Wire Cable Wrap Assortment Electric Insulation Heat Shrink Tube Kit (1 pcs)Please Choose Size Below

Price BDT 2
More
In-Stock
Jumper Wire Single Medium Quick view

Reference: 1354

Jumper Wire Single Medium

Length: 8.5 inches (Medium) Material: Copper Plated.EachPin Spacing: 2.54mm.Color: Colorfulcompatible with 2.54mm mil spacing pin headers.It can be used for PCB project, pc motherboard, etc.Allow you to plug and unplug easily for prototyping.Package Contents: 1 x Jumper Wire You will get only one pcs.

Price BDT 3
More
In-Stock
Jumper wire 40 Pcs Quick view

Reference: 31

Jumper Wire 40 Pcs Set

3 Types Available 1. Male to Male  2. Male to Female 3. Female-Female

Price BDT 90
More
In Stock
470 Ohm 1/4w - Pack of 5 Quick view

Reference: 245

Kiloohm (KΩ) 1/4w Resistors - Pack of 5

Choose your desire Resistor value from below: 

Price BDT 5
More
In Stock
Push Button Switch Quick view

Reference: 761

Push Button Switch

Push Button Switch

Price BDT 5
More
In-Stock
Buzzer Quick view

Reference: 766

Ohm (Ω) 1/4w Resistors - Pack of 5

Choose your desire Resistor value from below: 

Price BDT 5
More
In-Stock
5 mm Green LED (Pack of 5) Quick view

Reference: 768

5 mm Red LED (Pack of 5)

5 mm Red LED (Pack of 5)

Price BDT 5
More
In-Stock
Buzzer Quick view

Reference: 758

BC547 NPN Transistor

BC547 NPN Transistor

Price BDT 2
More
In-Stock
On sale! Arduino Uno R3 (Made in Italy) Quick view

Reference: 94

Arduino Uno R3

Arduino UNO in Bangladesh The Arduino Uno is a microcontroller board based on the ATmega328 (datasheet). It has 14 digital input/output pins (of which 6 can be used as PWM outputs), 6 analog inputs, a 16 MHz ceramic resonator, a USB connection, a power jack, an ICSP header, and a reset button. It contains everything needed to support the microcontroller.

Price BDT 428
More
In Stock
Buzzer Quick view

Reference: 755

5 mm Green LED (Pack of 5)

5 mm Green LED (Pack of 5)

Price BDT 5
More
In-Stock
All best sellers
    Omron
    • Omron

    Omron CJ1W-AD041-V1

    847
    Call For Price
    01783 007 004
    Quantity

    • Store Pickup Available! Store Pickup Available!
    • Free Ship Over 5000 BDT Free Ship Over 5000 BDT
    • Quality Product Quality Product
    • No Warranty No Warranty
    • No Replacement No Replacement
    Description

    Omron CJ1W-AD041-V1

     

    Analog Input Units CJ1W-AD041-V1/AD081-V1/AD042

     

     

    ItemCJ1W-AD041-V1CJ1W-AD081-V1CJ1W-AD042
    Unit typeCJ-series Special I/O Unit
    Isolation *1Between I/O and Controller signals: Photocoupler
    (No isolation between I/O signals.)
    Between I/O and Controller signals:
    Digital isolator (No isolation between I/O signals.)
    External terminals18-point detachable terminal block (M3 screws)
    Power consumption420 mA max. at 5 VDC520 mA max. at 5 VDC
    Dimensions (mm)31 × 90 × 65 mm (W × H × D)
    Weight140 g max.150 g max.
    General specificationsConforms to general specifications for CJ Series.
    Input
    specifi-
    cations
    Number of analog inputs484
    Input signal range *21 to 5 V
    0 to 5 V
    0 to 10 V
    - 10 to 10 V
    4 to 20 mA
    *3
    1 to 5 V
    0 to 10 V
    - 5 to 5 V
    - 10 to 10 V
    4 to 20 mA
    *4
    Maximum rated input
    (for 1 point) *5
    Voltage Input: ± 15 V
    Current Input: ± 30 mA
    Input impedanceVoltage Input: 1 MΩ min. Current Input: 250 Ω (rated value)
    Resolution4,000/8,000 *61 to 5 V10,000
    0 to 10 V20,000
    - 5 to 5 V20,000
    - 10 to 10 V40,000
    4 to 20 mA10,000
    Converted output data16-bit binary data
    Accuracy
    *7
    25 °C *8Voltage Input: ± 0.2% of F.S. Current Input: ± 0.4% of F.S.
    0 °C to 55 °CVoltage Input: ± 0.4% of F.S. Current Input: ± 0.6% of F.S.
    A/D conversion period *91 ms/250 μs per point *620 μs/1 point, 25 μs/2 points,
    30 μs/3 points, 35 μs/4 points
    Input
    functions
    Mean value processingStores the last "n" data conversions in the
    buffer, and stores the mean value of the
    conversion values.
    Buffer number: n = 2, 4, 8, 16, 32, 64
    Stores the last "n" data conversions in the
    buffer, and stores the mean value of the
    conversion values.
    Buffer number:
    n = 2, 4, 8, 16, 32, 64, 128, 256, 512
    Peak value holdingStores the maximum conversion value while the Peak Value Hold Bit is ON.
    Scaling---Setting values in any specified unit within a
    range of ±32,000 as the upper and lower limits
    allows A/D conversion to be executed and
    analog signals to be output with these values as
    full scale.
    Input disconnection
    detection
    Detects the disconnection and turns ON the Disconnection Detection Flag. *10
    Offset/gain adjustmentSupported---
    Direct conversion---A/D conversion is performed and the converted
    value is refreshed when the ANALOG INPUT
    DIRECT CONVERSION instruction (AIDC) is
    executed. This instruction is supported by the
    CJ2H-CPU[][](-EIP) CPU Units with unit version
    1.1 or later, and CJ2M-CPU[][].
    CJ1, NJ501, and CP1H CPU Units and NSJ
    Controllers do not support direct conversion.

     

     

     

    *1 Do not apply a voltage higher than 600 V to the terminal block when performing withstand voltage test on this Unit. 
          Otherwise, internal elements may deteriorate. 
    *2 Input signal ranges can be set for each input. 
    *3 Voltage input or current input are chosen by using the voltage/current switch at the back of the terminal block. 
    *4 To use a current input, connect the positive current input terminal and positive voltage input terminal with the enclosed 
          short bar. 
    *5 The Analog Input Unit must be operated according to the input specifications provided here. Operating the Unit outside 
          these specifications will cause the Unit to malfunction. 
    *6 The resolution can be set to 8,000 and the conversion period to 250 μs in the setting. There is only one setting for both 
          of these, i.e., they are both enabled or disabled together. 
    *7 The accuracy is given for full scale. For example, an accuracy of ±0.2% means a maximum error of ±8 (BCD) at a 
          resolution of 4,000. 
          For the CJ1W-AD041-V1/ AD081-V1, the default setting is adjusted for voltage input. To use current input, perform the 
          offset and gain adjustments as required. 
    *8 For the CJ1W-AD041-V1/ AD081-V1, 23±2°C. 
    *9 The A/D conversion period is the time required from when the Analog Input Unit receives the analog signal until it 
          stores the converted value in internal memory. It takes at least one cycle for the converted data to be stored in the 
          CPU Unit. (The direct conversion function of the CJ1W-AD042 is can be used to input data immediately to the CPU 
          Unit.) 
    *10 Line disconnection detection is supported only when the range is set to 1 to 5 V or 4 to 20 mA. If there is no input 
            signal when the 1 to 5 V or 4 to 20 mA range is set, the Line Disconnection Flag will turn ON.

     

     

    Analog Output Units CJ1W-DA021/DA041/DA08V/DA08C/DA042V

     

     

    ItemCJ1W-DA021CJ1W-DA041CJ1W-DA08VCJ1W-DA08CCJ1W-DA042V
    Unit typeCJ-series Special I/O Unit
    Isolation *1Between I/O and Controller signals:
    Photocoupler (No isolation between I/O signals.)
    Between I/O and
    Controller signals:
    Digital isolator (No
    isolation between
    I/O signals.)
    External terminals18-point detachable terminal block (M3 screws)
    Power consumption5 VDC, 120 mA max.5 VDC, 140 mA max.5 VDC, 400 mA max.
    External power supply *224 VDC +10% -15%,
    (inrush current: 20 A max., pulse width: 1 ms min.)
    ---
    140 mA max.200 mA max.140 mA max.170 mA max.---
    Dimensions (mm)31 × 90 × 65 mm (W × H × D)
    Weight150 g max.
    General specificationsConforms to general specifications for CJ-series Series.
    Output
    specifi-
    cations
    Number of analog outputs24884
    Output signal range *31 to 5 V/4 to 20 mA
    0 to 5 V
    0 to 10 V
    - 10 to 10 V
    1 to 5 V
    0 to 5 V
    0 to 10 V
    - 10 to 10 V
    4 to 20 mA1 to 5 V
    0 to 10 V
    - 10 to 10 V
    Output impedance0.5 Ω max. (for voltage output)0.5 Ω max. (for
    voltage output)
    ---0.5 Ω max.
    (for voltage output)
    Max. output current (for
    1 point)
    12 mA (for voltage output)2.4 mA (for
    voltage output)
    ---2 mA
    (for voltage output)
    Maximum permissible
    load resistance
    600 Ω (current output)---350 Ω---
    Resolution40,0004,000/8,000 *81 to 5 V10,000
    0 to 10 V20,000
    -10 to 10 V40,000
    Set data16-bit binary data
    Accuracy
    *4
    25 °CVoltage output: ± 0.3% of F.S.
    Current output: ± 0.5% of F.S.
    ± 0.3% of F.S.± 0.3% of F.S.± 0.3% of F.S.
    0 °C to 55 °CVoltage output: ± 0.5% of F.S.
    Current output: ± 0.8% of F.S.
    ± 0.5% of F.S.± 0.6% of F.S.± 0.5% of F.S.
    D/A conversion period *51.0 ms per point1.0 ms or 250 μs per point *820 μs/1 point,
    25 μs/2 points,
    30 μs/3 points,
    35 μs/4 points
    Output
    functions
    Output hold functionOutputs the specified output status (CLR, HOLD, or MAX) under any of the following
    circumstances.
    When the Conversion Enable Bit is OFF. *6
    In adjustment mode, when a value other than the output number is output during adjustment. *7
    When output setting value error occurs or Controller operation stops.
    When the Load is OFF.
    Scaling---Supported only for a conversion
    period of 1 ms and resolution of
    4,000.
    Setting values in any specified
    unit within a range of ± 32,000
    as the upper and lower limits
    allows D/A conversion to be
    executed and analog signals to
    be output with these values as
    full scale.
    Setting values in any
    specified unit within a
    range of ±32,000 as the
    upper and lower limits
    allows D/A conversion to
    be executed and analog
    signals to be output with
    these values as full scale.
    Offset/gain adjustmentSupported---
    Direct conversion---D/A conversion is
    performed and the output
    value is refreshed when
    the ANALOG OUTPUT
    DIRECT CONVERSION
    instruction (AODC) is
    executed. This instruction
    is supported by the CJ2H-
    CPU[][](-EIP) CPU Units
    with unit version 1.1 or
    later, and CJ2M-CPU[][].
    CJ1, NJ501, and CP1H
    CPU Units and NSJ
    Controllers do not support
    direct conversion.

     

     

     

    *1 Do not apply a voltage higher than 600 V to the terminal block when performing withstand voltage test on this Unit. 
    *2 The maximum number of Analog Output Units that can be mounted to one Rack varies depending on the current 
          consumption of the other Units mounted to the Rack. 
          Select a 24 VDC power supply based on the surge current. The following OMRON external power supplies with a 
          power rating of 50 W are recommended.

     

     

     

    ManufacturerModel numberSpecifications
    OMRONS8VS-06024100 to 240 VAC, 60 W
    S8VS-12024100 to 240 VAC, 120 W
    S8VM-05024100 to 240 VAC, 50 W
    S8VM-10024100 to 240 VAC, 100 W

     

     

     

    *3 Output signal ranges can be set for each output. 
    *4 The accuracy is given for full scale. For example, an accuracy of ±0.3% means a maximum error of ±60 mV for a −10 
          to 10 V range. For the CJ1W-DA021/041, the accuracy is at the factory setting for a current output. When using a 
          voltage output, adjust the offset gain as required. 
    *5 The D/A conversion period is the time required for the Analog Output Unit to convert and output the data that was 
          received from the CPU Unit. 
          It takes at least one cycle for the data stored in the CPU Unit to be read by the Analog Output Unit. (The direct 
          conversion function of the CJ1WDA042V can be used to output data immediately from the CPU Unit.) 
    *6 When the operation mode for the CPU Unit is changed from RUN mode or MONITOR mode to PROGRAM mode, or 
          when the power is turned ON, the Output Conversion Enable Bit will turn OFF. The output status specified according 
          to the output hold function will be output. 
    *7 The CJ1W-DA042V does not have an Adjustment Mode. 
    *8 The CJ1W-DA08V/08C can be set to a conversion cycle of 250 μs and a resolution of 8,000 using the setting.

     

     

    Analog I/O Unit CJ1W-MAD42

     

    Specifications

     

     

    ItemCJ1W-MAD42
    Unit typeCJ-series Special I/O Unit
    IsolationBetween I/O and Controller signals: Photocoupler (No isolation between I/O signals.)
    External terminals18-point detachable terminal block (M3 screws)
    Current consumption580 mA max. at 5 V DC
    Dimensions (mm)31 × 90 × 65 mm (W × H × D)
    Weight150 g max.
    General specificationsConforms to general specifications for CJ-series Series.

     

     

    Input Specifications and Functions

     

     

    ItemVoltage inputCurrent input
    Number of analog inputs4
    Input signal range *11 to 5 V
    0 to 5 V
    0 to 10 V
    - 10 to 10 V
    4 to 20 mA *2
    Maximum rated input (for
    1 point) *3
    ± 15 V± 30 mA
    Input impedance1 M Ω min.250 Ω (rated value)
    Resolution4,000/8,000 *7
    Converted output data16-bit binary data
    Accuracy
    *4
    25 °C± 0.2% of F.S.
    0 °C to 55 °C± 0.4% of F.S.
    A/D conversion period *51.0 ms/500 μ s per point *7
    Mean value processingStores the last "n" data conversions in the buffer, and stores the mean value of the conversion values.
    Buffer number: n = 2, 4, 8, 16, 32, 64
    Peak value holdingStores the maximum conversion value while the Peak Value Hold Bit is ON.
    ScalingEnabled only for conversion period of 1 ms and resolution of 4,000. Setting any values within a range of
    ± 32,000 as the upper and lower limits allows the A/D conversion result to be output with these values
    as full scale.
    Input disconnection detectionDetects the disconnection and turns ON the Disconnection Detection Flag.
    Offset/gain adjustmentSupported

     

     

    Output Specifications

     

     

    ItemVoltage outputCurrent output
    Number of analog outputs2
    Output signal range *11 to 5 V
    0 to 5 V
    0 to 10 V
    - 10 to 10 V
    4 to 20 mA
    Output impedance0.5 Ω max.-
    Maximum external output
    current (for 1 point)
    2.4 mA-
    Maximum allowed load
    resistance
    -600 Ω
    Resolution4,000/8,000 *7
    Set data16-bit binary data
    Accuracy
    *4
    25 °C± 0.3% of F.S.± 0.3% of F.S.
    0 °C to 55 °C± 0.5% of F.S.± 0.6% of F.S.
    D/A conversion period *51.0 ms/500 μs per point
    Output hold functionOutputs the specified output status (CLR, HOLD, or MAX) under any of the following circumstances.
    When the Conversion Enable Bit is OFF. *6
    In adjustment mode, when a value other than the output number is output during adjustment.
    When output setting value error occurs or Controller operation stops.
    When the Load is OFF.
    ScalingEnabled only for conversion period or 1 ms and resolution of 4,000. Setting any values within a range of
    ± 32,000 as the upper and lower limits allows D/A conversion to be executed and analog signals to be
    output with these values as full scale.
    Ratio conversion function
    *5
    Stores the results of positive and negative gradient analog inputs calculated for ratio and bias as analog
    output values.
    Positive gradient: Analog output = A × Analog input + B (A: 0 to 99.99, B: 8000 to 7FFF hex)
    Negative gradient: Analog output = F - A × Analog input + B (A: 0 to 99.99, B: 8000 to 7FFF hex,
    F: Output range maximum value)
    Offset/gain adjustmentSupported


    Product Details
    847
    24 other products in the same category:
    Omron Quick view

    Reference: 861

    Omron CQM1-ID212

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 856

    Omron CJ1W-OD233

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 849

    Omron CJ1W-ID211

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 869

    Omron CPM1A-20CDR-A

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 864

    Omron CQM1-CPU11

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 868

    Omron CPM1A-20EDR1

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 845

    Omron CJ1G CPU45H

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 854

    Omron CJ1W-OD202

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 857

    Omron CJ1W-OD262

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 858

    Omron CJ1W-SCU41-V1

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 850

    Omron CJ1W-ID231

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 865

    Omron CQM1-0D212

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 866

    Omron CPM2A-60CDR-A

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 862

    Omron CQM1-IA121

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 851

    Omron CJ1W-ID232

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 846

    Omron CJ1M-CPU11

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 859

    Omron Cj1w-ii101

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 863

    Omron CQM1H-CPU51

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 853

    Omron CJ1W-OC211

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 867

    Omron CPM1A-40CDR-D-V1

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 860

    Omron CQM1-PA203

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 852

    Omron CJ1W-MD233

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 848

    Omron CJ1W-IC101

    Call For Price 01783 007 004

    More
    In stock
    Omron Quick view

    Reference: 855

    Omron CJ1W-OD212

    Call For Price 01783 007 004

    More
    In stock

    Follow us on Facebook