Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: 1353
Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Selecting the most reliable sensor for any Application is quite tricky as you need to think over various specs like its size, accuracy, operating specifications, and most importantly, its price. Here, we carry around 150+ differential sensors with all technical specifications and its application guidelines to narrow down your search filters which gives the highest level of satisfaction to you. Explore a wide range of best-picked sensors by Robotics Bangladesh from top brands at sensible prices in Bangladesh.
Subcategories
Reference: RBD-0041
Bases at CSR BC04 Bluetooth technology. with build-in 2.4GHz PCB antenna It’s at the Bluetooth class 2 power level. Range test: 10 meters Operating voltage: 3.3V to 6V DC Operating current in pairing is in the range of 30~40mA.
Reference: RBD-0149
Output Channel: 1 Power Supply: 3.3/5V Built in a potentiometer for sensitivity control. Onboard signal output indication, output effective signal is high, at the same time the indicator light up, the output signal can directly connect to microcontroller IO. Detection angle about 60 degrees, the flame spectrum especially sensitive. The flame of the most...
Reference: RBD-0291
Main chip: LM393, Electret condenser microphone Working voltage: DC 3.3-5V Induction distance is 0.5M Signal output Indication Single channel signal output The output effective signal is low level.
Reference: RBD-0431
Working temperature : -10℃ ~ 50℃ Working humidity : below saturation point Storage temperature : -20℃ ~ 80℃ RoboticsBD
Reference: RBD-0311
Working Voltage: 5 to 18V DC (min tested working voltage 4.5V). RoboticsBD Max current draw: 15mA @ 5V. Working Flow Rate: 1 to 30 Liters/Minute. Maximum water pressure: 2.0 MPa. Flow rate pulse characteristics: Frequency (Hz) = 7.5 * Flow rate (L/min). RoboticsBD
Reference: RBD-0423
Detecting range: >120 degree Analog and digital outputs On-board potentiometer and indicators 1% resistors to make this module more reliable and precise Operating Voltage: 3.3V – 9V Board Diameter: 40 mm.
Reference: RBD-0550
Supply Voltage: 4.5 – 5.5 V. Current : <40 mA. Digital Interface : 5V TTL level for UART interface and GPIO. Support maximum 80 voice commands, with each voice 1500ms (one or two words speaking). Maximum 7 voice commands effective at same time. Arduino library is supplied. User-control General Pin Output. RoboticsBD
Reference: RBD-0671
Operating Voltage:+5V Preheat Duration:20 s Analog Output Voltage:0 to 5 V Dimension:36x20x21 mm. RoboticsBD
Reference: RBD-0355
Description:Working voltage: 4.5V to 5.5 V.Transmit tube pressure drop: Vf = 1.6 VTransmit tube current: 20 mASignal output: A, B two way; The TTL levelDistinguish precision: 0.01 mmMeasurement frequency, 100 KHZEncoder diameter: 24 mmEncoder type D hole diameter: 4 mmThe encoder resolution: 20 line
Reference: RBD-0672
Power requirements: 5 VDC @ ~165 mA (heater on) / ~60 mA (heater off). Current Consumption: 150mA. RoboticsBD DO output: 0.1 and 5V. AO output: 0.1- 0.3 V (relative to pollution), the maximum concentration of a voltage of about 4V Detecting Concentration: 0.05-10mg/L Alcohol.
Reference: RBD-0690
The main chip: ISD1820. Operating Voltage: DC 3V-5V. Loudspeaker: 8Ω, 0.5W. An easy to use 10 seconds of voice recording. High-quality, natural voice restored. Can be used as a propaganda module. With looping, jog playback, single-pass play function.
Reference: RBD-0823
LDR module 4 PIN Operating voltage 3.3V-5V Signal output indicator light. LDR module 4 PIN Able to detect ambient brightness and light intensity Adjustable sensitivity (via blue digital potentiometer adjustment)
Reference: RBD-0411
Low current consumption (typical 30 mA) CW or pulse operation Flat profile Long detection range (20 m) Supply voltage: 4.75V to 5.25V X-Band Frequency: 10.525 GHz Minimum Power Output: 13 dBm EIRP. RoboticsBD
Reference: RBD-0673
Detecting range: 300~10000ppm Signal output indicator. Dual Signal output (analog output and TTL output). The TTL output signal is low level, allows us to connect with SCM directly. Analog output 0~5V voltage. Quick response and recovery. RoboticsBD
Reference: RBD-1022
Main chip: LM393, Electret condenser microphone Working voltage: DC 3.3-5V Induction distance is 0.5M Signal output Indication Single channel signal output The output effective signal is low level.
Reference: RBD-2100
Comparator chip LM393 makes module readings stable. Operating voltage 3.3V-5V. Fast Response Time Sensitivity adjustable Detects a flame or a light source of a wavelength in the range of 760nm-1100 nm. Detection range: up to 100 cm. Adjustable detection range. Detection angle about 60 degrees, it is sensitive to the flame spectrum.
Reference: RBD-0427
Working voltage: 3.3V-5V Output form: digital output (0 and 1)
Reference: RBD-0674
Model: MQ-5 Operating Voltage: 5V DC Operating Temparature:-20~40 degree celcius
Reference: RBD-1324
Operating voltage: 2.5V-5.5V Maximum output power: 3W x 2 PCB size is about: length 30mm width 22mm overall height after installed is about 16mm Built with switch Potentiometer, can adjust the volume & control power switch freely! Flexible assembly usage.
Reference: RBD-0664
Supply Voltage: 3.3 V/ 5V. Interface Type: I²C, SPI. Sensing Range: ±2g, ±4g, ±8g, ±16g. Sensitivity X: 28.6 LSB/g. Sensitivity Y: 31.2 LSB/g. Sensitivity Z: 34.5 LSB/g. Ultra Low Power: 40µA in measurement mode, 0.1µA in standby@ 2.5V. Free-Fall Detection. Tap/Double Tap Detection. RoboticsBD
Reference: RBD-0675
Model: MQ-6 Operating Voltage: 5V DC Detecting Range:200-10000 ppm Relative Humidity:<95% RH
Reference: RBD-1738
Operating Voltage : 1.5 ~ 15V DC Working Current: Less than 25mA Tone Generation Range : 1.5 ~ 2.5kHz Dimensions (LxWxH): 26 x 15 x 11 mm
Reference: RBD-0676
Operating voltage: DC 5 V. The analog output voltage, the higher the concentration the higher the voltage. The carbon monoxide detection with better sensitivity. With a long service life and reliable stability. Rapid response and recovery characteristics. Range: 10 to 1000 ppm. RoboticsBD
Reference: RBD-0693
Operating Voltage: 3-5.5V Supply Current: ≥ 20mA Optimal Sensing Distance: 3mm Working voltage of 5V, the output of the black line low, white line of high output Uses Infrared Light to Detect Anti-Interference Ability Sensors to adopt TCRT5000 High Sensitivity, Stable Performance Exquisite workmanship, with the indicator Has a fixed bolt hole for easy...
Reference: RBD-1753
Digital I2S interface with high precision 24-bit dataHigh signal to noise ratio is 61 dBAHigh sensitivity – 26 dBFSStable frequency response from 60 Hz to 15 kHzLow power consumption: low current consumption 1.4 mAHigh PSR: -75 dBFS
Reference: RBD-0677
Using high-quality dual-panel design, with power indicator and TTL signal output instructions. The switching signal having a DO (TTL) output and analog output AO. TTL output valid signal is low. The higher the voltage, the concentration of the analog output voltage is higher. A hydrogen gas detection with good sensitivity. Has a long life and reliable...
Reference: RBD-0822
S49E hall sensor Features wide-range voltage comparator LM393 Signal output indicator Analog / Digital output
Reference: RBD-1773
Supply Voltage: 5V USB / 3.7V lithium battery Output Port: 3-wire audio interface/DIY pad Output Type: Analog signal Bluetooth name: VHM-314-V3.0 Bluetooth version: 5.0 Bluetooth passcode: no password Sound source: Bluetooth. USB-PC input(after the back pad is connected, the computer can be connected as a sound card though Micro) Operation method:...
Reference: RBD-0678
Good sensitivity to CO/Combustible Gas High sensitivity to Methane, Propane, and CO Long life and low cost Simple drive circuit Input voltage: DC 5±0.2V Current Consumption: 150mA
Reference: RBD-1192
Digital Output Hall-effect sensor. Operating voltage: typically 5V. Output Current: 25mA. It can be used to detect both the poles of a magnet.
Reference: RBD-1772
Small size package Local voice Customized voice wake-up/command words Universal Serial Port Protocol Support Chinese and English The number of command words reaches 150
Reference: RBD-0679
Sensitivity to Ammonia, Sulfide and Benzene steam Sensitive for benzene, alcohol, smoke Fast response and recovery Adjustable sensitivity. RoboticsBD Signal output indicator Output voltage boosts along with the concentration of the measured gases increases.