Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: 1353
Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0414
A probe by new original installation import DS18B20 temperature sensor chip. RoboticsBD Chip each pin use heat shrinkable tube to prevent short circuit, internal sealing glue, waterproof, moistureproof. Stainless steel tube encapsulation waterproof moistureproof prevent rust. Stainless steel shell (6 * 45 mm), lead length 100 cm (shielding wire) use...
Reference: RBD-0416
Onboard 8 key TTP226 capacitive touch induction IC. RoboticsBD Onboard 8-way level indicator. Working voltage: 2.4 to 5.5 V. Modules, you can set the output mode, key output mode, the longest time and fast/low power output
Reference: RBD-0424
SI7021 SHT21 HTV21 Wide operating voltage (1.9 to 3.6 V) – 3.3 V Recommended Precision Relative Humidity Sensor ± 3% RH (max), 0–80% RH High Accuracy Temperature Sensor ±0.4 °C (max), –10 to 85 °C Interchangeable - No recalibration required. RoboticsBD I2C Interface
Reference: RBD-1873
Operating Voltage: 4-30V VDC It is a 2-wire display. LED Color: Red Current Consumption: Less than 20mA, generally 5-15mA Accuracy: 0.1 V. Refresh Speed: Approx 300mS/time.
Reference: RBD-2178
Mini grabber SMD IC test hook for logic analyzer Retractable hook with 2mm inner spring Perfect for continuity testing of circuit board components Can be used to test IC, repair cell phone, or other mini electronic products Double Dupont plug lead for connecting to logic analyzer or oscilloscope Note: You will receive random color. If you order 2pcs you...
Reference: RBD-2180
Testing hook clip multimeters test lead extension probe Safety handle and spring hook type alligator clip Converting connection for probes with whorl pattern Made of high quality material, durable to use and provide great performance Compact design, easy to carry
Reference: RBD-0555
Low-noise analog signal path Device bandwidth is set via the new FILTER pin 5 µs output rise time in response to step input current Small footprint, low-profile SOIC8 package 2.1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8 Supply Voltage: 4.5V~5.5V DC Measure Current Range: 30A Sensitivity: 100mV/A
Reference: RBD-2224
Voltage – 250V Easy PCB mounting Good consistency Widely acclaimed
Reference: RBD-0622
Transmission signal processing control chip RCWL-9196 Wide operating voltage range 4.0V to 28.0V Penetrating detection capability, compared with the traditional infrared feeling PIR Adjustable Block time and distance Operating Current: 2.8mA (typical); 3mA (max) Detection Distance: 5-9m Transmitting Power: 20mW (typical); 30mW (max) RoboticsBD
Reference: RBD-2340
2 Channel PWM Pulse Frequency Adjustable Duty Cycle Square Wave Rectangular Wave Signal Generator Module to generate square wave for experiment development. This is used to drive stepping motor drivers' square waves, Generate an adjustable pulse for MCU using, and Generate an adjustable pulse for controlling the relative circuit (PWM adjust lightspeed, etc).
Reference: RBD-0665
Operating voltage: 5V Provide both digital and analog output Adjustable sensitivity. RoboticsBD Output LED indicator Compatible with Arduino TTL Compatible Bolt holes for easy installation
Reference: RBD-2453
Fully self contained panel meter with dual red and blue display.
Reference: RBD-0667
Input Supply Voltage (VDC): 3.3 ~ 5. Supply Current (mA): measurement 0.3mA standby 60μA. Temperature measurement range: 0~50 degrees. Temperature measurement error: ±2 degrees. Humidity measurement range: 20%~95%RH. Humidity measurement error: ±5%RH. RoboticsBD
Reference: RBD-2464
Three WiresUltra-low cost, high precision to meet most of the application requirements.low starting working voltage blue minimum 5.0V.
Reference: RBD-0668
Crystal 32.768KHz, matching capacitance 6pF DS1302 8-pin SMD homemade chips Seconds, Minutes, Hours, Day of Month, Day of Week, and Year Operating temperature: 0 degree — 70 degree. RoboticsBD
Reference: RBD-0671
Operating Voltage:+5V Preheat Duration:20 s Analog Output Voltage:0 to 5 V Dimension:36x20x21 mm. RoboticsBD
Reference: RBD-0672
Power requirements: 5 VDC @ ~165 mA (heater on) / ~60 mA (heater off). Current Consumption: 150mA. RoboticsBD DO output: 0.1 and 5V. AO output: 0.1- 0.3 V (relative to pollution), the maximum concentration of a voltage of about 4V Detecting Concentration: 0.05-10mg/L Alcohol.
Reference: RBD-0673
Detecting range: 300~10000ppm Signal output indicator. Dual Signal output (analog output and TTL output). The TTL output signal is low level, allows us to connect with SCM directly. Analog output 0~5V voltage. Quick response and recovery. RoboticsBD
Reference: RBD-0674
Model: MQ-5 Operating Voltage: 5V DC Operating Temparature:-20~40 degree celcius
Reference: RBD-0675
Model: MQ-6 Operating Voltage: 5V DC Detecting Range:200-10000 ppm Relative Humidity:<95% RH
Reference: RBD-0676
Operating voltage: DC 5 V. The analog output voltage, the higher the concentration the higher the voltage. The carbon monoxide detection with better sensitivity. With a long service life and reliable stability. Rapid response and recovery characteristics. Range: 10 to 1000 ppm. RoboticsBD
Reference: RBD-0677
Using high-quality dual-panel design, with power indicator and TTL signal output instructions. The switching signal having a DO (TTL) output and analog output AO. TTL output valid signal is low. The higher the voltage, the concentration of the analog output voltage is higher. A hydrogen gas detection with good sensitivity. Has a long life and reliable...
Reference: RBD-2686
Operating current: 20mA Operating voltage: DC 4.5 ~ 30V Minimum resolution(V): 0.1V Minimum resolution(A): 0.01A Display color: Red and Blue (two-color display) Measure accuracy: 1% Dual Led 0.28 ” Display for DC0-100V 100A Voltage and Current Test Digital Instrument, Digital Meter Panel Amplifier Red Blue 100A
Reference: RBD-0678
Good sensitivity to CO/Combustible Gas High sensitivity to Methane, Propane, and CO Long life and low cost Simple drive circuit Input voltage: DC 5±0.2V Current Consumption: 150mA
Reference: RBD-0679
Sensitivity to Ammonia, Sulfide and Benzene steam Sensitive for benzene, alcohol, smoke Fast response and recovery Adjustable sensitivity. RoboticsBD Signal output indicator Output voltage boosts along with the concentration of the measured gases increases.
Reference: RBD-0687
Operating Voltage: 1.71V to 3.6V – would typically be operated from 3.3V. Operating Temperature: -40 to +85 deg. Celsius (full accuracy between 0 and +65 deg. C). Peak current: 1.12mA. RoboticsBD Operating Pressure: 300 hPa to 1100 hPa. Accuracy between 700 to 900hPa and 25 to 40 deg. C: ±0.12hPa and ±1.0m.
Reference: RBD-0689
Operating Voltage: 2.8 V to 5.5 V Accuracy: ± 1.5°C Zero power resistance: 100 KΩ Operating temperature range: -55 ~ +125 ℃
Reference: RBD-0690
The main chip: ISD1820. Operating Voltage: DC 3V-5V. Loudspeaker: 8Ω, 0.5W. An easy to use 10 seconds of voice recording. High-quality, natural voice restored. Can be used as a propaganda module. With looping, jog playback, single-pass play function.
Reference: RBD-0693
Operating Voltage: 3-5.5V Supply Current: ≥ 20mA Optimal Sensing Distance: 3mm Working voltage of 5V, the output of the black line low, white line of high output Uses Infrared Light to Detect Anti-Interference Ability Sensors to adopt TCRT5000 High Sensitivity, Stable Performance Exquisite workmanship, with the indicator Has a fixed bolt hole for easy...
Reference: RBD-0922
Dimensions: 91 x 21 x 30 mm(LxWxH) Weight: 18 gm. Voltage: 3.3V or 5V. Port: Analog. Resistance: 10K. Appn: Raspberry-Pi projects. DIY projects., Arduino projects.
Reference: RBD-1022
Main chip: LM393, Electret condenser microphone Working voltage: DC 3.3-5V Induction distance is 0.5M Signal output Indication Single channel signal output The output effective signal is low level.
Reference: RBD-1066
Operating voltage: 5V DC. Detector distance: 1CM. Adjust the potentiometer, let the modules work normally. Small and easy to use module. It comes with a Buzzer for metal detection indication.The Mini Metal Detector Module arrives disassembled, requiring assembly using a soldering iron and soldering accessories. Moderate knowledge of soldering and...